Installation
E E EKSH26P
DAIKIN Solar P-SYS
008.1629544_01 – 12/2016
Planning and installation instructions
19
4.4
Mounting the flat solar panels
Carry out the following steps:
1. Hook the solar panel securing clips in the guide groove of the
lower mounting profile and tilt downwards.
When fitted, the securing clips can be easily pushed side-
ways.
Tab. 4-3 Clearance dimensions of the securing clips
2. Lift the flat solar panel onto the roof area using a crane. If no
crane is available, the solar panel can be hoisted onto the roof
with a rope, using a ladder leaning against the roof edge. De-
pending on the installation requirements, unpack the solar
panel before or after the transport to the roof and remove the
collection pipe protective plugs.
3. Lift the covered solar panel above the mounting profile, set
down and carefully hook into the securing clips. Always begin
with the left outer solar panel.
4. Move the flat solar panel sideways until the left-hand outer
ends of the two mounting rails project approx. 25 mm beyond
the solar panel's edge.
If necessary, correct the alignment of the upper mounting pro-
file and finally screw tight.
Push the single terminal blocks from the left side into the
mounting profiles (flush closure) and screw tight (fig. 4-7).
The solar panel mounting and the hydraulic connection
is only carried out after installation of the requisite sub-
construction. All assembly information for the sub-
construction or the roof integration of the DAIKIN Solar
flat solar panels are given in the respective quick instructions
which accompany the
●
roof-mounted assembly packages
●
in-roof assembly packages
●
flat roof assembly packages.
●
Fix the upper mounting profile in place in such a way that the
lateral alignment can still be corrected.
In the pressurised solar system, the installation open-
ings of the solar panel temperature sensor must be in
the upper area of the flat solar panel.
Fig. 4-5
Step 1: Alignment of the securing clips
(Legend, see tab. 4-1; Dimensions, see tab. 4-3)
EKSV21P
EKSV26P
EKSH26P
A0
100 – 250
A1
650 – 850
800 – 1100
1600 – 1800
A2
240 – 440
The flat solar panel must be lifted onto the roof in the
correct orientation for mounting (prevents faults during
connection or difficult manoeuvring operations). The
top side of the solar panel (P) is marked on the protec-
tive cover of the solar panel glazing. The plugs for the solar
panel temperature sensor and the round solar panel connection
seals must at the bottom when aligning the flat solar panel.
A
0
A
1
A
1
A
2
A
0
2b
2b
(8)
(9)
2b
Solar panel securing clips
Fig. 4-6
Step 3
CAUTION!
In order to prevent torsional stresses and fixing
difficulties when mounting the solar panels,
●
slightly tighten the self-locking nuts of the
slide blocks,
●
align both mounting profiles exactly level and
parallel to one another. If needed, the
mounting profiles inserted in suitable way.
For the roof-mounted system (ADM), the equipotential
bonding terminal is attached close to the inflow connec-
tion (top); in contrast, for the in-roof system (IDM) and
flat roof system (FDM), it is attached close to the return
flow connection (bottom).
2b
2b