Planning and installation instructions
22
E E EKSH26P
DAIKIN Solar P-SYS
008.1629544_01 – 12/2016
4
x
Installation
2. Insert the solar panel connecting elbows into the solar panel
connecting pipe until the retaining clips audibly engage.
Install the return flow connection at the bottom and the two-
way inflow connection at the top if possible.
3. Insert the sealing plugs into the open solar panel connection
pipes until the retaining clamps click in place.
4. Mark and cut off the required length of the inflow (top) and re-
turn flow pipes (bottom). Then deburr the pipe ends.
5. Slide the heat insulation hoses onto the connection pipes or
solar panel connecting elbows and cut to the required length.
6. Connect the inflow and return flow pipes to the cutting ring
screw fittings of the solar panel connecting elbows and the
connection set.
7. Slide the compressed heat insulation hose over the solar pan-
el connecting elbow.
Fig. 4-14 Work step 2
Fig. 4-15 Work step 3
Fig. 4-16 Step 4
Fig. 4-17 Step 5
Click
Click
A
Union nut
B
Support sleeve
C
Cutting ring
D
Fitting
Fig. 4-18 Step 6
Fig. 4-19 Step 7
1.
3.
2.
4.
L
A
A
A
A
B
B
B
C
C
C