EKHBRD011~Y1

Indoor unit for air to water heat pump system and options

4P402192-1A – 2015.04

Operation manual

12

Domestic water heating

Domestic water heating can be done through several standard
operation modes:

Automatic storage: by field setting, once during night and/or
once during the afternoon the water is heated till storage set
point.

Manual storage: if due to special circumstances, production
of hot water (till storage set point) is needed immediately
(1 time), this function can be used.

Reheat: the reheat function can be activated next to or
separate from the automatic storage operation if the user
wants to keep the domestic hot water tank at the minimum
reheat temperature.

Next to the standard domestic water heating operation modes, it is
also possible to freely program the domestic water heating operation
through the schedule timer (refer to 

"Programming quiet mode or

domestic water heating" on page 14

). Then the mode is switched on

or off at a scheduled time. Five actions can be programmed per
mode. These actions are repeated daily (additional schedule of
storage on top of the automatic day and night storage functionality).

Quiet mode

Refer to 

"Programming quiet mode or domestic water heating" on

page 14

.

Switch the mode on or off at a scheduled time. Five actions can be
programmed per mode. These actions are repeated daily.

Programming and consulting the schedule timer

Programming the schedule timer is flexible (you can add, remove or
alter programmed actions whenever required) and straightforward
(programming steps are limited to a minimum). However, before
programming the schedule timer, remind:

Familiarize yourself with the icons and the buttons. You will need
them when programming. Refer to 

"Remote controller buttons

and icons" on page 3

.

Fill out the form at the very end of this manual. This form can
help you define the required actions for each day. Keep in mind
that:
-

In the space heating program, depending on remote 
controller model 4 or 5 actions can be programmed per 
weekday. The same actions are repeated on a weekly basis.

-

In the domestic water heating and quiet mode program, 
depending on remote controller model 4 or 5 actions can be 
programmed per mode. The same actions are repeated on a 
daily basis.

Take your time to enter all data accurately.

Try to program the actions in a chronological way: start with
action 1 for the first action and end with the highest number for
the last action. This is not a requirement but will simplify the
interpretation of the program later.

If 2 or more actions are programmed for the same day and at the
same time, only the action with the highest action number will be
executed.

Example:

You can always alter, add or remove the programmed actions
later.

NOTE

Remark that only the time when domestic water
heating must start and stop can be programmed
in the schedule timer. When domestic water
heating is enabled, the water will be heated till
storage set point. The storage set point is set
through field setting.

For energy-saving reasons, keep hours with low
electricity cost tariffs in mind when programming
the schedule timer for domestic water heating.

NOTE

If the auto restart function is disabled, the
schedule timer will not be activated when power
returns to the unit after a power supply failure.
Press the 

 button to enable the schedule timer

again.

When power returns after a power supply failure,
the auto restart function reapplies the user
interface settings at the time of the power supply
failure (if time is shorter than 2 hours). It is
therefore recommended to leave the auto restart
function enabled.

The programmed schedule is time driven.
Therefore, it is essential to set the clock and the
day of the week correctly.

Refer to 

"Setting the clock" on page 4

.

When the schedule timer is not enabled (  icon
not displayed), schedule timer actions will not be
executed!

The programmed actions are not stored according
to their timing but according to the time of
programming. This means that the action that was
programmed  first gets action number 1, even
though it is executed after other programmed
action numbers.

NOTE

Remote controller model: 4 actions

Remote controller model: 5 actions

Programmed actions

Executed actions

Time 

(hour)

Temperature 

(°C)

Time 

(hour)

Temperature 

(°C)

1

16:00

22

1

06:00

21

2

18:00

OFF

2

08:00

23

3

08:00

23

3

16:00

22

4

06:00

21

4

18:00

OFF

5

18:00

26

Summary of Contents for EKHBRD011ADV1

Page 1: ...OPERATION MANUAL EKHBRD011ADV1 EKHBRD014ADV1 EKHBRD016ADV1 EKHBRD011ADY1 EKHBRD014ADY1 EKHBRD016ADY1 Indoor unit for air to water heat pump system and options...

Page 2: ...y or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children sh...

Page 3: ...sh the button See Automatic storage on page 7 The icon will display Hot water will be produced at next scheduled action When water heat up starts the icon will be blinking 1 second interval Manual sto...

Page 4: ...installation purposes only 13 NOT AVAILABLE This icon is displayed whenever a non installed option is addressed or a function is not available A function not available can mean insufficient permissio...

Page 5: ...on as well as the shift value in case not zero will display 31 ROOM TEMPERATURE ADJUST BUTTONS and These multi purpose buttons are used to adjust the current room temperature set point in normal opera...

Page 6: ...ater temperature control In this mode heating will be activated as required by the water temperature set point The set point can be set manually through the schedule timer or weather dependent automat...

Page 7: ...ings 3 00 Low ambient temperature Lo_A low outdoor temperature 3 01 High ambient temperature Hi_A high outdoor temperature 3 02 Set point at low ambient temperature Lo_Ti the target outgoing water tem...

Page 8: ...atus defines whether the weather dependent domestic water heating is turned ON 1 or OFF 0 If enabled the storage set point will be set weather dependent In case of a higher ambient temperature e g dur...

Page 9: ...point for the domestic hot water storage temperature is reached It can also be stopped at any time by pushing the button NOTE If weather dependent domestic water heating is enabled b 02 the storage t...

Page 10: ...lf is done by the heater kit If there are no error conditions in leaving or returning water thermistors the heater kit can start to follow emergency operation Other operation modes Start up operation...

Page 11: ...lation is controlled by the schedule timer The actions programmed in the schedule timer will be executed automatically The schedule timer is enabled icon displayed or disabled icon not displayed by pr...

Page 12: ...ommand 13 00 and will remain active until the next programmed command 19 00 occurs So in order to know the actual setting one should consult the last programmed command It is clear that the last progr...

Page 13: ...water heating and quiet mode program depending on remote controller model 4 or 5 actions can be programmed per mode The same actions are repeated on a daily basis Take your time to enter all data accu...

Page 14: ...emperature 10 Use the and buttons to set the room temperature 11 Use the button to select to switch heating and the remote controller off to select automatic temperature calculation for leaving water...

Page 15: ...tions If the button is pressed when action number 3 is displayed actions 1 2 and 3 are stored but 4 and 5 are deleted By pressing the button several times you return to previous steps in this procedur...

Page 16: ...actions except those with a higher action number than the one that is displayed E g when the button is pressed when action number 3 is displayed actions 1 2 and 3 are stored but 4 and 5 are deleted D...

Page 17: ...ceed as follows 1 Press the button for a minimum of 5 seconds to enter FIELD SET MODE The icon 3 will be displayed The current selected field setting code is indicated 2 with the set value displayed t...

Page 18: ...A 15 10 20 1 C 02 Set point at low ambient temperature Lo_Ti 70 25 80 1 C 03 Set point at high ambient temperature Hi_Ti 45 25 80 1 C 4 Disinfection function 00 Status disinfection operation 1 ON 0 1...

Page 19: ...storage temperature 70 45 75 1 C 04 Automatic maximum hot water tank storage temperature 70 55 75 1 C C Leaving water temperature limits 00 Installation related setting 80 37 80 1 C 01 Installation r...

Page 20: ...the system yourself the dismantling of the system treatment of the refrigerant of oil and other parts must be done by a qualified installer in accordance with relevant local and national legislation...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...4P402192 1A 2015 04 Copyright 2015 Daikin...

Reviews: