The configuration of the Daikin system is done through field settings.

In this operation manual all field settings related to the operation of
the unit and user demand are explained. A list of all those field
settings and default values is given under 

"Field settings table" on

page 17

. In this same list, we provided for 2 columns to register the

date and value of altered field settings at variance with the default
value.

For a total list of field settings, refer to the installation manual.

All field settings are accessible and programmable through the user
interface on the indoor unit.

Each field setting is assigned a 3-digit number or code, for example
[5-03], which is indicated on the user interface display. The first digit
[5] indicates the 'first code' or field setting group. The second and
third digit [03] together indicate the 'second code'. 

Procedure

To change one or more field settings, proceed as follows.

1

Press the 

 button for a minimum of 5 seconds to enter FIELD

SET MODE.
The 

 icon (3) will be displayed. The current selected field

setting code is indicated 

 (2), with the set value displayed to

the right 

 (1).

2

Press the 

 button to select the appropriate field setting

first code.

3

Press the 

 button to select the appropriate field setting

second code.

4

Press the 

 button and 

 button to change

the set value of the select field setting.

5

Save the new value by pressing the 

 button.

6

Repeat step 2 through 4 to change other field settings as
required.

7

When finished, press the 

 button to exit FIELD SET MODE.

NOTE

Changes made to a specific  field setting are only
stored when the 

 button is pressed. Navigating to a

new  field setting code or pressing the 

 button will

discard the change made.

NOTE

Before shipping, the set values have been set as
shown under 

"Field settings table" on page 17

.

When exiting FIELD SET MODE, "

88

" may be

displayed on the remote controller LCD while the
unit initializes itself.

2

3

1

When running through the field settings you may notice
that there are some more field settings as there are
mentioned in the 

"Field settings table" on page 17

These

field settings are not applicable and may not be
changed!

Summary of Contents for EKHBRD011ADV1

Page 1: ...OPERATION MANUAL EKHBRD011ADV1 EKHBRD014ADV1 EKHBRD016ADV1 EKHBRD011ADY1 EKHBRD014ADY1 EKHBRD016ADY1 Indoor unit for air to water heat pump system and options...

Page 2: ...y or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children sh...

Page 3: ...sh the button See Automatic storage on page 7 The icon will display Hot water will be produced at next scheduled action When water heat up starts the icon will be blinking 1 second interval Manual sto...

Page 4: ...installation purposes only 13 NOT AVAILABLE This icon is displayed whenever a non installed option is addressed or a function is not available A function not available can mean insufficient permissio...

Page 5: ...on as well as the shift value in case not zero will display 31 ROOM TEMPERATURE ADJUST BUTTONS and These multi purpose buttons are used to adjust the current room temperature set point in normal opera...

Page 6: ...ater temperature control In this mode heating will be activated as required by the water temperature set point The set point can be set manually through the schedule timer or weather dependent automat...

Page 7: ...ings 3 00 Low ambient temperature Lo_A low outdoor temperature 3 01 High ambient temperature Hi_A high outdoor temperature 3 02 Set point at low ambient temperature Lo_Ti the target outgoing water tem...

Page 8: ...atus defines whether the weather dependent domestic water heating is turned ON 1 or OFF 0 If enabled the storage set point will be set weather dependent In case of a higher ambient temperature e g dur...

Page 9: ...point for the domestic hot water storage temperature is reached It can also be stopped at any time by pushing the button NOTE If weather dependent domestic water heating is enabled b 02 the storage t...

Page 10: ...lf is done by the heater kit If there are no error conditions in leaving or returning water thermistors the heater kit can start to follow emergency operation Other operation modes Start up operation...

Page 11: ...lation is controlled by the schedule timer The actions programmed in the schedule timer will be executed automatically The schedule timer is enabled icon displayed or disabled icon not displayed by pr...

Page 12: ...ommand 13 00 and will remain active until the next programmed command 19 00 occurs So in order to know the actual setting one should consult the last programmed command It is clear that the last progr...

Page 13: ...water heating and quiet mode program depending on remote controller model 4 or 5 actions can be programmed per mode The same actions are repeated on a daily basis Take your time to enter all data accu...

Page 14: ...emperature 10 Use the and buttons to set the room temperature 11 Use the button to select to switch heating and the remote controller off to select automatic temperature calculation for leaving water...

Page 15: ...tions If the button is pressed when action number 3 is displayed actions 1 2 and 3 are stored but 4 and 5 are deleted By pressing the button several times you return to previous steps in this procedur...

Page 16: ...actions except those with a higher action number than the one that is displayed E g when the button is pressed when action number 3 is displayed actions 1 2 and 3 are stored but 4 and 5 are deleted D...

Page 17: ...ceed as follows 1 Press the button for a minimum of 5 seconds to enter FIELD SET MODE The icon 3 will be displayed The current selected field setting code is indicated 2 with the set value displayed t...

Page 18: ...A 15 10 20 1 C 02 Set point at low ambient temperature Lo_Ti 70 25 80 1 C 03 Set point at high ambient temperature Hi_Ti 45 25 80 1 C 4 Disinfection function 00 Status disinfection operation 1 ON 0 1...

Page 19: ...storage temperature 70 45 75 1 C 04 Automatic maximum hot water tank storage temperature 70 55 75 1 C C Leaving water temperature limits 00 Installation related setting 80 37 80 1 C 01 Installation r...

Page 20: ...the system yourself the dismantling of the system treatment of the refrigerant of oil and other parts must be done by a qualified installer in accordance with relevant local and national legislation...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...4P402192 1A 2015 04 Copyright 2015 Daikin...

Reviews: