EKHBRD011~Y1
Indoor unit for air to water heat pump system and options
4P402192-1A – 2015.04
Operation manual
16
Field settings
The configuration of the Daikin system is done through field settings.
In this operation manual all field settings related to the operation of
the unit and user demand are explained. A list of all those field
settings and default values is given under
"Field settings table" on
page 17
. In this same list, we provided for 2 columns to register the
date and value of altered field settings at variance with the default
value.
For a total list of field settings, refer to the installation manual.
All field settings are accessible and programmable through the user
interface on the indoor unit.
Each field setting is assigned a 3-digit number or code, for example
[5-03], which is indicated on the user interface display. The first digit
[5] indicates the 'first code' or field setting group. The second and
third digit [03] together indicate the 'second code'.
Procedure
To change one or more field settings, proceed as follows.
1
Press the
button for a minimum of 5 seconds to enter FIELD
SET MODE.
The
icon (3) will be displayed. The current selected field
setting code is indicated
(2), with the set value displayed to
the right
(1).
2
Press the
button to select the appropriate field setting
first code.
3
Press the
button to select the appropriate field setting
second code.
4
Press the
button and
button to change
the set value of the select field setting.
5
Save the new value by pressing the
button.
6
Repeat step 2 through 4 to change other field settings as
required.
7
When finished, press the
button to exit FIELD SET MODE.
NOTE
Changes made to a specific field setting are only
stored when the
button is pressed. Navigating to a
new field setting code or pressing the
button will
discard the change made.
NOTE
■
Before shipping, the set values have been set as
shown under
"Field settings table" on page 17
.
■
When exiting FIELD SET MODE, "
88
" may be
displayed on the remote controller LCD while the
unit initializes itself.
2
3
1
When running through the field settings you may notice
that there are some more field settings as there are
mentioned in the
"Field settings table" on page 17
. These
field settings are not applicable and may not be
changed!