background image

Operation manual

15

EKHBRD011~Y1

Indoor unit for air to water heat pump system and options

4P402192-1A – 2015.04

Tips and tricks

Programming the next day(s)

After confirming the programmed actions of a specific day (i.e. after
pressing the   button for 5 seconds), press the 

 button once. You

can now select another day by using the 

 and 

 buttons

and restart consulting and programming.

Copying programmed actions to next day

In space heating program it is possible to copy all programmed
actions of a specific day to the next day (e.g. copy all programmed
actions from "

" to "

").

To copy programmed actions to the next day, proceed as follows:

1

Press the   button to enter the programming/consulting mode.

The actual mode is blinking.

2

Select the operation mode you would like to program by means
of the 

 and 

 buttons.

The actual mode is blinking.

You can leave programming by pressing the 

 button.

3

Press the   button to confirm the selected mode.

The actual day is blinking.

4

Select the day you would like to copy to the next day by means
of the 

 and 

 buttons.

The selected day is blinking.

You can return to step 

2

 by pressing the 

 button.

5

Press the   and 

 buttons simultaneously for 5 seconds.

After 5 seconds the display will show the next day (e.g. "

" if "

"

was selected first). This indicates that the day has been copied.

You can return to step 

2

 by pressing the 

 button.

Deleting one or more programmed actions

Deleting one or more programmed actions is done at the same time
as storing the programmed actions.

When all actions for one day have been programmed, make sure that
the display shows the highest action number you would like to save.
By pressing the   button for 5 seconds, you store all actions except
those with a higher action number than the one that is displayed.

E.g. when the   button is pressed when action number 3 is
displayed, actions 1, 2 and 3 are stored but 4 and 5 are deleted.

Deleting a mode

1

Press the   button to enter the programming/consulting mode.

2

Select the operation mode you would like to delete by means of
the 

 and 

 buttons.

The actual mode is blinking.

3

Press the   and 

 button simultaneously for 5 seconds to

delete the selected mode.

Deleting a day of the week

1

Press the   button to enter the programming/consulting mode.

2

Select the operation mode you would like to delete by means of
the 

 and 

 buttons.

The actual mode is blinking.

3

Press the   button to confirm the selected mode.

The actual day is blinking.

4

Select the day you would like to delete by means of the 
and 

 buttons.

The selected day is blinking.

5

Press the   and 

 button simultaneously for 5 seconds to

delete the selected day.

Operating the remote alarm option

An optional EKRP1HBA digital I/O PCB can be connected to the
indoor unit and be used to remotely monitor your system. This
address card offers 3 voltage free outputs:

Output 1 = THERMO ON/OFF 

this output will be enabled when your unit is in space heating
operation.

Output 2 = ALARM OUTPUT 

this output will be enabled when your unit is in error condition.

Output 3 = DOMESTIC HOT WATER MODE ON/OFF

this output will be enabled when your unit is in domestic water
heating operation.

For more details about the wiring connections of this option, refer to
the wiring diagram of the unit.

Operating the optional remote controller

If besides the main remote controller the optional remote controller is
installed as well, the main remote controller (master) can access all
settings while the second remote controller (slave) can not access
schedule settings and parameter settings.

Refer to the installation manual for more details.

Summary of Contents for EKHBRD011ADV1

Page 1: ...OPERATION MANUAL EKHBRD011ADV1 EKHBRD014ADV1 EKHBRD016ADV1 EKHBRD011ADY1 EKHBRD014ADY1 EKHBRD016ADY1 Indoor unit for air to water heat pump system and options...

Page 2: ...y or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children sh...

Page 3: ...sh the button See Automatic storage on page 7 The icon will display Hot water will be produced at next scheduled action When water heat up starts the icon will be blinking 1 second interval Manual sto...

Page 4: ...installation purposes only 13 NOT AVAILABLE This icon is displayed whenever a non installed option is addressed or a function is not available A function not available can mean insufficient permissio...

Page 5: ...on as well as the shift value in case not zero will display 31 ROOM TEMPERATURE ADJUST BUTTONS and These multi purpose buttons are used to adjust the current room temperature set point in normal opera...

Page 6: ...ater temperature control In this mode heating will be activated as required by the water temperature set point The set point can be set manually through the schedule timer or weather dependent automat...

Page 7: ...ings 3 00 Low ambient temperature Lo_A low outdoor temperature 3 01 High ambient temperature Hi_A high outdoor temperature 3 02 Set point at low ambient temperature Lo_Ti the target outgoing water tem...

Page 8: ...atus defines whether the weather dependent domestic water heating is turned ON 1 or OFF 0 If enabled the storage set point will be set weather dependent In case of a higher ambient temperature e g dur...

Page 9: ...point for the domestic hot water storage temperature is reached It can also be stopped at any time by pushing the button NOTE If weather dependent domestic water heating is enabled b 02 the storage t...

Page 10: ...lf is done by the heater kit If there are no error conditions in leaving or returning water thermistors the heater kit can start to follow emergency operation Other operation modes Start up operation...

Page 11: ...lation is controlled by the schedule timer The actions programmed in the schedule timer will be executed automatically The schedule timer is enabled icon displayed or disabled icon not displayed by pr...

Page 12: ...ommand 13 00 and will remain active until the next programmed command 19 00 occurs So in order to know the actual setting one should consult the last programmed command It is clear that the last progr...

Page 13: ...water heating and quiet mode program depending on remote controller model 4 or 5 actions can be programmed per mode The same actions are repeated on a daily basis Take your time to enter all data accu...

Page 14: ...emperature 10 Use the and buttons to set the room temperature 11 Use the button to select to switch heating and the remote controller off to select automatic temperature calculation for leaving water...

Page 15: ...tions If the button is pressed when action number 3 is displayed actions 1 2 and 3 are stored but 4 and 5 are deleted By pressing the button several times you return to previous steps in this procedur...

Page 16: ...actions except those with a higher action number than the one that is displayed E g when the button is pressed when action number 3 is displayed actions 1 2 and 3 are stored but 4 and 5 are deleted D...

Page 17: ...ceed as follows 1 Press the button for a minimum of 5 seconds to enter FIELD SET MODE The icon 3 will be displayed The current selected field setting code is indicated 2 with the set value displayed t...

Page 18: ...A 15 10 20 1 C 02 Set point at low ambient temperature Lo_Ti 70 25 80 1 C 03 Set point at high ambient temperature Hi_Ti 45 25 80 1 C 4 Disinfection function 00 Status disinfection operation 1 ON 0 1...

Page 19: ...storage temperature 70 45 75 1 C 04 Automatic maximum hot water tank storage temperature 70 55 75 1 C C Leaving water temperature limits 00 Installation related setting 80 37 80 1 C 01 Installation r...

Page 20: ...the system yourself the dismantling of the system treatment of the refrigerant of oil and other parts must be done by a qualified installer in accordance with relevant local and national legislation...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...4P402192 1A 2015 04 Copyright 2015 Daikin...