7 Installation
Installer reference guide
36
EKCB
EK2CB EKMBU EKMBUHCA9W1
Daikin Altherma low temperature monobloc
4P405544-1 – 2015.03
NOTICE
Make sure that the marks (2 by 2) are completely level and
that their dimensions correspond to the figure below.
318 mm
310 mm
3
Drill 4 holes and install 4 plugs (suitable for M5).
4
Put the screws in the top plugs and hang the box on the
screws.
5
Put the screws in the bottom plugs.
6
Fix the 4 screws firmly.
7.6
Mounting the backup heater
7.6.1
About mounting the backup heater
NOTICE
▪ The backup heater can only be installed and used in
combination with the outdoor unit and control box
EKCB07CAV3.
▪ The backup heater can only be connected to the space
heating water outlet of the outdoor unit. Other
connections are NOT allowed.
▪ Only one backup heater can be connected to the
outdoor unit. It is NOT allowed to combine multiple
heater kits in series or parallel.
{Niels, 03/02/2015 08:56:15:
Confirmation required
}
7.6.2
Precautions when mounting the backup
heater
INFORMATION
Also read the precautions and requirements in the
following chapters:
▪ General safety precautions
▪ Preparation
7.6.3
To install the backup heater
1
Fix the wall bracket to the wall with M5 screws.
2×
2
Hang the backup heater onto the wall bracket.
3
Mark the position of the hole at the bottom of the backup
heater.
4
Remove the backup heater from the wall bracket.
5
Drill a hole for the bottom screw and insert a plug.
6
Hang the backup heater onto the wall bracket. Make sure it is
fixed properly.
7
Fix the bottom of the backup heater to the wall with an M5
screw.