Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
A.3.2.3
[2-09]
R/W
-5~5°C, step: 0,5°C
0°C
A.3.2.4
R/W
0: 0,5 °C
1: 1 °C
└─
Operation range
A.3.3.1
[4-02]
R/W
14~35 °C, step: 1°C
25°C
A.3.3.2
[F-01]
R/W
10~35°C, step: 1°C
20°C
└─
Domestic hot water (DHW)
└─
Type
A.4.1
[6-0D]
R/W
0: Reheat only
1: sched.
2: Scheduled only
└─
Disinfection
A.4.4.1
[2-01]
R/W
0: No
1: Yes
A.4.4.2
[2-00]
R/W
0: Each day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Sunday
A.4.4.3
[2-02]
R/W
0~23 hour, step: 1 hour
23
A.4.4.4
[2-03]
R/W
55~80°C, step: 5°C
70°C
A.4.4.5
[2-04]
R/W
5~60 min, step: 5 min
10 min
└─
Maximum setpoint
A.4.5
[6-0E]
R/W
40~80°C, step: 1°C
60°C
└─
SP mode
A.4.6
R/W
0: Fixed
1: Weather dep.
└─
Weather dependent curve
A.4.7
[0-0B]
Weather-dependent curve
Leaving water value for high ambient temp. for
DHW WD curve.
R/W
35~[6-0E]°C, step: 1°C
55°C
A.4.7
[0-0C]
Weather-dependent curve
Leaving water value for low ambient temp. for
DHW WD curve.
R/W
45~[6-0E]°C, step: 1°C
60
°C
A.4.7
[0-0D]
Weather-dependent curve
High ambient temp. for DHW WD curve.
R/W
10~25°C, step: 1°C
15°C
A.4.7
[0-0E]
Weather-dependent curve
Low ambient temp. for DHW WD curve.
R/W
-40~5°C, step: 1°C
-10°C
└─
Heat sources
└─
Backup heater
A.5.1.1
[4-00]
R/W
0~2
0: Disabled
1: Enabled
A.5.1.2
R/W
0: Manual
1: Automatic
A.5.1.3
[4-07]
R/W
0: No
1: Yes
A.5.1.4
[5-01]
R/W
-15~35°C, step: 1°C
-4°C
└─
System operation
└─
Auto restart
A.6.1
[3-00]
R/W
0: No
1: Yes
└─
Preferential kWh rate
A.6.2.1
[D-00]
R/W
0: None
1: BSH only
2: BUH only
3: All heaters
A.6.2.2
[D-05]
R/W
0: Forced off
1: As normal
└─
Pwr consumpt. Control
A.6.3.1
[4-08]
R/W
0: No limitation
1: Continuous
2: Digital inputs
A.6.3.2
[4-09]
R/W
0: Current
1: Power
A.6.3.3
[5-05]
R/W
0~50 A, step: 1 A
50 A
A.6.3.4
[5-09]
R/W
0~20 kW, step: 0,5 kW
20 kW
A.6.3.5.1
[5-05]
Amp. limits for DI
Limit DI1
R/W
0~50 A, step: 1 A
50 A
A.6.3.5.2
[5-06]
Amp. limits for DI
Limit DI2
R/W
0~50 A, step: 1 A
50 A
A.6.3.5.3
[5-07]
Amp. limits for DI
Limit DI3
R/W
0~50 A, step: 1 A
50 A
A.6.3.5.4
[5-08]
Amp. limits for DI
Limit DI4
R/W
0~50 A, step: 1 A
50 A
A.6.3.6.1
[5-09]
kW limits for DI
Limit DI1
R/W
0~20 kW, step: 0,5 kW
20 kW
A.6.3.6.2
[5-0A]
kW limits for DI
Limit DI2
R/W
0~20 kW, step: 0,5 kW
20 kW
A.6.3.6.3
[5-0B]
kW limits for DI
Limit DI3
R/W
0~20 kW, step: 0,5 kW
20 kW
A.6.3.6.4
[5-0C]
kW limits for DI
Limit DI4
R/W
0~20 kW, step: 0,5 kW
20 kW
A.6.3.7
[4-01]
R/W
0: None
1: BSH
2: BUH
└─
Averaging time
A.6.4
[1-0A]
R/W
0: No averaging
1: 12 hours
2: 24 hours
3: 48 hours
4: 72 hours
└─
Ext amb. sensor offset
A.6.5
[2-0B]
R/W
-5~5°C, step: 0,5°C
0°C
└─
Boiler efficiency
Space cooling On temp
Ext. room sensor offset
Space heating OFF temp
Disinfection
Operation day
Start time
Room temp. step
Temperature target
Duration
Operation mode
Emergency
Enable BUH step 2
Equilibrium temp.
Allowed heaters
Forced pump OFF
Mode
Type
Amp. value
kW value
Priority
4P405542-1 - 2015.03
(*1) *B*_(*2) *D*