Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
A.8
[4-04]
R/W
0: Continuous pump operation
1: Intermittent pump operation
2: No protection
A.8
[4-05]
0
A.8
[4-06]
0/1
A.8
[4-07]
R/W
0: No
1: Yes
A.8
[4-08]
R/W
0: No limitation
1: Continuous
2: Digital inputs
A.8
[4-09]
R/W
0: Current
1: Power
A.8
[4-0A]
0
A.8
[4-0B]
R/W
1~10°C, step: 0,5°C
1°C
A.8
[4-0D]
R/W
1~10°C, step: 0,5°C
3°C
A.8
[4-0E]
Is the installer on site?
R/W
0: No
1: Yes
A.8
[5-00]
R/W
0: Allowed
1: Not allowed
A.8
[5-01]
R/W
-15~35°C, step: 1°C
-4°C
A.8
[5-02]
R/W
0: Disabled
1: Enabled
A.8
[5-03]
R/W
-15~35°C, step: 1°C
0°C
A.8
[5-04]
R/W
0~20°C, step: 1°C
10°C
A.8
[5-05]
R/W
0~50 A, step: 1 A
50 A
A.8
[5-06]
R/W
0~50 A, step: 1 A
50 A
A.8
[5-07]
R/W
0~50 A, step: 1 A
50 A
A.8
[5-08]
R/W
0~50 A, step: 1 A
50 A
A.8
[5-09]
R/W
0~20 kW, step: 0,5 kW
20 kW
A.8
[5-0A]
R/W
0~20 kW, step: 0,5 kW
20 kW
A.8
[5-0B]
R/W
0~20 kW, step: 0,5 kW
20 kW
A.8
[5-0C]
R/W
0~20 kW, step: 0,5 kW
20 kW
A.8
[5-0D]
R/W
0~5
1: 1P,(1/1+2)
4: 3PN,(1/2)
5: 3PN,(1/1+2)
A.8
[5-0E]
1
A.8
[6-00]
R/W
2~20°C, step: 1°C
2°C
A.8
[6-01]
R/W
0~10°C, step: 1°C
2°C
A.8
[6-02]
R/W
0~10kW, step: 0,2kW
3kW
A.8
[6-03]
R/W
0~10kW, step: 0,2kW
3kW
A.8
[6-04]
R/W
0~10kW, step: 0,2kW
0kW
A.8
[6-05]
0
A.8
[6-06]
0
A.8
[6-07]
0
A.8
[6-08]
R/W
2~20°C, step: 1°C
10°C
A.8
[6-09]
0
A.8
[6-0A]
R/W
30~[6-0E]°C, step: 1°C
55°C
A.8
[6-0B]
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
A.8
[6-0C]
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
A.8
[6-0D]
R/W
0: Reheat only
1: sched.
2: Scheduled only
A.8
[6-0E]
R/W
40~80°C, step: 1°C
60°C
A.8
[7-00]
R/W
0~4°C, step: 1°C
0°C
A.8
[7-01]
R/W
2~40°C, step: 1°C
2°C
A.8
[7-02]
R/W
0: 1 LWT zone
1: 2 LWT zones
A.8
[7-03]
2,5
A.8
[7-04]
0
A.8
[7-05]
R/W
0: Very high
1: High
2: Medium
3: Low
4: Very low
A.8
[8-00]
1 min
A.8
[8-01]
R/W
5~95 min, step: 5 min
30 min
A.8
[8-02]
R/W
0~10 hour, step: 0,5 hour
3 hour
A.8
[8-03]
R/W
20~95 min, step: 5 min
50 min
A.8
[8-04]
R/W
0~95 min, step: 5 min
95 min
A.8
[8-05]
R/W
0: No
1: Yes
A.8
[8-06]
R/W
0~10°C, step: 1°C
3°C
A.8
[8-07]
R/W
[9-03]~[9-02], step: 1°C
18°C
A.8
[8-08]
R/W
[9-03]~[9-02], step: 1°C
20°C
How to protect the water pipes from freezing
--
-- (Do not change this value)
Enable the second step of the backup heater?
Which power limitation mode is required on the system?
Which power limitation type is required?
--
Automatic cooling/heating changeover hysteresis.
Automatic cooling/heating changeover offset.
Is backup heater operation allowed above equilibrium temperature during space
heating operation?
What is the equilibrium temperature for the building?
Space heating priority.
Space heating priority temperature.
Set point correction for domestic hot water temperature.
What is the requested limit for DI1?
What is the requested limit for DI2?
What is the requested limit for DI3?
What is the requested limit for DI4?
What is the requested limit for DI1?
What is the requested limit for DI2?
What is the requested limit for DI3?
What is the requested limit for DI4?
What type of backup heater installation is used?
--
The temperature difference determining the heat pump ON temperature.
The temperature difference determining the heat pump OFF temperature.
What is the capacity of the booster heater?
What is the capacity of the backup heater step 1?
What is the capacity of the backup heater step 2?
--
--
--
What is the hysteresis to be used in reheat mode?
--
What is the desired comfort storage temperature?
What is the desired eco storage temperature?
What is the desired reheat temperature?
What is the desired DHW production type?
What is the maximum temperature setpoint?
Domestic hot water booster heater overshoot temperature.
Domestic hot water booster heater hysteresis.
How many leaving water temperature zones are there?
--
--
Boiler efficiency
--
Maximum running time for domestic hot water operation.
Anti-recycling time.
Booster heater delay timer.
Additional running time for the maximum running time.
Allow modulation of the LWT to control the room temp?
Leaving water temperature maximum modulation.
What is the desired comfort main LWT in cooling?
What is the desired eco main LWT in cooling?