![Daikin DP13GM2404541A series Technical Manual Download Page 14](http://html1.mh-extra.com/html/daikin/dp13gm2404541a-series/dp13gm2404541a-series_technical-manual_2460482014.webp)
14
BLOWER PERFORMANCE DATA
Unit
Static
CFM
W A TTS A MP S
RIS E
CFM
W ATTS A MPS
RISE
CFM
W A TTS A MP S
RIS E
0.1
1,100
340
1.55
62
1,450
480
2.15
47
1,575
585
2.64
NR
0.2
1,040
325
1.49
66
1,390
460
2.06
49
1,515
565
2.58
45
0.3
1,000
320
1.44
68
1,300
445
1.98
52
1,430
550
2.50
48
0.4
925
305
1.38
74
1,215
425
1.89
56
1,340
525
2.42
51
0.5
860
290
1.32
NR
1,115
395
1.79
61
1,240
505
2.34
55
0.6
800
275
1.22
NR
1,030
375
1.71
66
1,130
465
2.22
60
0.7
690
255
1.16
NR
945
350
1.60
72
1,010
450
2.18
67
0.8
--------
--------
--------
NR
860
335
1.54
NR
910
430
2.12
75
DP13GM 4209041A* - Rise Ra nge : 45° - 75°
LOW
MEDIUM
HIGH
Unit
Static
CFM
W A TTS A MPS
RISE
CFM
W ATTS AM PS
RIS E
CFM
W ATTS AMP S
RIS E
0.1
1,100
340
1.55
46
1,450
480
2.15
35
1,575
585
2.64
NR
0.2
1,040
325
1.49
49
1,390
460
2.06
37
1,515
565
2.58
NR
0.3
1,000
320
1.44
51
1,300
445
1.98
39
1,430
550
2.50
36
0.4
925
305
1.38
55
1,215
425
1.89
42
1,340
525
2.42
38
0.5
860
290
1.32
59
1,115
395
1.79
46
1,240
505
2.34
41
0.6
800
275
1.22
64
1,030
375
1.71
50
1,130
465
2.22
45
0.7
690
255
1.16
NR
945
350
1.60
54
1,010
450
2.18
51
0.8
--------
--------
--------
NR
860
335
1.54
59
910
430
2.12
56
DP 13GM4207041A* - Rise Ra nge : 35° - 65°
LOW
MEDIUM
HIGH
Unit
Static
CFM
W A TTS A MP S
RIS E
CFM
W ATTS A MPS
RISE
CFM
W A TTS A MP S
RIS E
0.1
1,029
346
1.51
50
1,337
471
2.08
39
1,462
596
2.64
35
0.2
982
334
1.46
53
1,265
452
2.01
41
1,398
563
2.58
37
0.3
946
329
1.40
55
1,227
448
1.97
42
1,326
550
2.50
39
0.4
888
313
1.38
58
1,159
429
1.87
45
1,260
534
2.42
41
0.5
823
304
1.29
63
1,073
405
1.73
48
1,188
513
2.34
44
0.6
750
287
1.23
NR
1,008
393
1.71
51
1,090
496
2.22
47
0.7
668
271
1.16
NR
895
371
1.61
58
997
478
2.18
52
0.8
454
238
1.00
NR
760
346
1.49
68
852
454
2.12
61
DP 13GM3607041A* - Rise Ra nge : 35° -65°
LOW
MEDIUM
HIGH
Unit
Static
CFM
W A TTS A MPS
RISE
CFM
W ATTS AM PS
RIS E
CFM
W ATTS AMP S
RIS E
0.1
1,029
346
1.51
34
1,337
471
2.08
NR
1,462
596
2.64
NR
0.2
982
334
1.46
35
1,265
452
2.01
NR
1,398
563
2.58
NR
0.3
946
329
1.40
36
1,227
448
1.97
NR
1,326
550
2.50
NR
0.4
888
313
1.38
39
1,159
429
1.87
30
1,260
534
2.42
NR
0.5
823
304
1.29
42
1,073
405
1.73
32
1,188
513
2.34
NR
0.6
750
287
1.23
46
1,008
393
1.71
34
1,090
496
2.22
32
0.7
668
271
1.16
52
895
371
1.61
39
997
478
2.18
35
0.8
454
238
1.00
NR
760
346
1.49
45
852
454
2.12
40
LOW
MEDIUM
HIGH
DP 13GM3604541A* - Rise Ra nge : 30 -60°
NR = Heating Temperature Rise Not Recommeded.
NOTE:
The shaded area indicates ranges in excess of maximum external static pressure allowable when heating. For satisfactory operation,
external static pressure should not exceed 0.5" w.c.
DP13GM[36-42]***41A*
Unit
Static
CFM
W ATTS A M P S
RIS E
CFM
W ATTS AM P S
RIS E
CFM
W A TTS A M PS
RIS E
0.1
1,029
346
1.51
68
1,337
471
2.08
52
1,462
596
2.64
48
0.2
982
334
1.46
71
1,265
452
2.01
55
1,398
563
2.58
50
0.3
946
329
1.40
74
1,227
448
1.97
57
1,326
550
2.50
53
0.4
888
313
1.38
NR
1,159
429
1.87
60
1,260
534
2.42
55
0.5
823
304
1.29
NR
1,073
405
1.73
65
1,188
513
2.34
59
0.6
750
287
1.23
NR
1,008
393
1.71
69
1,090
496
2.22
64
0.7
668
271
1.16
NR
895
371
1.61
NR
997
478
2.18
70
0.8
454
238
1.00
NR
760
346
1.49
NR
852
454
2.12
NR
DP 13GM 3609041A* - Rise Ra nge : 45° -75°
LOW
M EDIUM
HIGH