10
PACKAGE GAS SPECIFICATIONS
DP13GM24045
41A*
DP13GM24070
41A*
DP13GM30045
41A*
DP13GM30070
41A*
DP13GM36045
41A*
COOLING
COOLING CAPACITY, BTUH
23,600
23,600
28,600
28,600
35,000
CAPACITY
SEER / EER
13.0 / 11.0
13.0 / 11.0
13.0 / 11.0
13.0 / 11.0
13.0 / 11.0
HEATING INPUT BTUH (U.S. & CANADIAN)
46,000
69,000
46,000
69,000
46,000
HEATING
HEATING OUTPUT BTUH (U.S. & CANADIAN)
36,700
55,000
36,700
55,000
36,700
CAPACITY
AFUE (%)
80
80
80
80
80
TEMPERATURE RISE (°F)
30 - 60
35 - 65
30 - 60
35 - 65
30 - 60
UNIT
VOLTAGE (NAMEPLATE)
208/230
208/230
208/230
208/230
208/230
ELECTRICAL
UNIT AMPS (TOTAL)
16.1
16.1
17.5
17.5
21.2
SPECIFICATION
MINIMUM CIRCUIT AMPACITY
19.5
19.5
20.9
20.9
25.4
MAXIMUM OVERCURRENT PROTECTION
(3)
30
30
35
35
40
HEATING
NUMBER OF BURNERS
2
3
2
3
2
SECTION
ORIFICE SIZE NATURAL
43
43
43
43
43
ORIFICE SIZE LP
55
55
55
55
55
COMPRESSOR
TYPE
Scroll
Scroll
Scroll
Scroll
Scroll
RATED LOAD AMPS
13.5
13.5
14.1
14.1
16.7
LOCKED ROTOR AMPS
58.3
58.3
73.0
73.0
79.0
CONDENSER
HORSEPOWER
1/6
1/6
1/4
1/4
1/4
FAN MOTOR
RPM
830
830
1100
1100
830
FULL LOAD AMPS
1.1
1.1
1.4
1.4
1.5
LOCKED ROTOR AMPS
3.0
3.0
2.9
2.9
3.0
CONDENSER
BLADE DIAMETER (INCHES)
22
22
22
22
22
FAN
NUMBER OF BLADES
3
3
3
3
3
CFM
2400
2400
2700
2700
2400
CONDENSER
FACE AREA - SQ. FT.
12.31
12.31
12.31
12.31
8.77
COIL
NUMBER OF ROWS
1
1
1
1
2
FINS PER INCH
24
24
24
24
27
EVAPORATOR
HORSEPOWER - NO. OF SPEEDS
1/4 - 3
1/4 - 3
1/3 - 3
1/3 - 3
1/3 - 3
BLOWER
FULL LOAD AMPS
1.5
1.5
1.9
1.9
3.1
MOTOR
LOCKED ROTOR AMPS
2.2
2.2
3.1
3.1
4.1
MOTOR SPEED TAP - COOLING
Med
Med
Med
Med
High
RPM
952
952
1,015
1,015
910
EVAPORATOR
DIAMETER X WIDTH (INCHES)
10” x 8”
10” x 8”
10” x 8”
10” x 8”
10” x 9”
BLOWER
RATED SCFM COOLING
800
800
1000
1000
1250
MAX EXTERNAL STATIC PRESS ("w.c.)
0.5
0.5
0.5
0.5
0.5
EVAPORATOR
FACE AREA - SQ. FT.
4.33
4.33
4.33
4.33
4.33
COIL
NUMBER OF ROWS
3
3
4
4
4
FINS PER INCH
14
14
14
14
14
FILTER SIZE - SQ. FT.
(2)
2.7
2.7
3.3
3.3
4.2
DRAIN SIZE (INCHES)
3/4
3/4
3/4
3/4
3/4
HEATING
PRIMARY LIMIT SETTING (°F)
150
150
150
150
160
LIMITS
AUXILIARY LIMIT SETTING (°F)
150
150
150
150
150
ROLLOUT LIMIT SETTING (°F)
350
350
350
350
350
GENERAL
PISTON EXPANSION DEVICE
Orifice (.057)
Orifice (.057)
Orifice (.062)
Orifice (.062)
Orifice (.068)
INFORMATION
REFRIGERANT CHARGE R-410A (Oz.)
75
75
78
78
70
POWER SUPPLY ENTRANCE SIZE (INCHES)
1 1/8
1 1/8
1 1/8
1 1/8
1 1/8
LOW VOLTAGE ENTRANCE SIZE (INCHES)
7/8
7/8
7/8
7/8
7/8
SHIPPING WEIGHT LBS.
420
425
421
425
470
OPERATING WEIGHT LBS.
396
397
397
399
449
DP13GM[24-36]***41A*
(1)
Units installed in Canada are certifed only to 4500 feet.
(2)
Calculated external filter size based on air velocity of 300 ft/min. and applies to disposable filters
only.
(3)
Maximum Overcurrent Protection Device:
MUST
use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.
IMPORTANT:
While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/
circuit breakers in accordance with the National Electrical Code and/or all local codes.