PACKAGE GAS SPECIFICATIONS
DP13GM[48-60]***41A*
(1)
Units installed in Canada are certifed only to 4500 feet.
(2)
Calculated external filter size based on air velocity of 300 ft/min. and applies to disposable filters
only.
(3)
Maximum Overcurrent Protection Device:
MUST
use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.
IMPORTANT:
While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/
circuit breakers in accordance with the National Electrical Code and/or all local codes.
DP13GM48090
41A*
DP13GM48115
41A*
DP13GM60090
41A*
DP13GM60115
41A*
DP13GM60140
41A*
COOLING
COOLING CAPACITY, BTUH
46,000
46,000
57,000
57,000
57,000
CAPACITY
SEER / EER
13.0 / 11.0
13.0 / 11.0
13.0 / 10.75
13.0 / 10.75
13.0 / 10.75
HEATING INPUT BTUH (U.S. & CANADIAN)
92,000
115,000
92,000
115,000
138,000
HEATING
HEATING OUTPUT BTUH (U.S. & CANADIAN)
73,600
92,000
73,600
92,000
110,400
CAPACITY
AFUE (%)
80
80
80
80
80
TEMPERATURE RISE (°F)
45 - 75
45-75
45 - 75
45 - 75
45 - 75
UNIT
VOLTAGE (NAMEPLATE)
208/230
208/230
208/230
208/230
208/230
ELECTRICAL
UNIT AMPS (TOTAL)
27.1
27.1
35.4
35.4
35.4
SPECIFICATION
MINIMUM CIRCUIT AMPACITY
32.1
32.1
42.0
42.0
42.0
MAXIMUM OVERCURRENT PROTECTION
50
50
60
60
60
HEATING
NUMBER OF BURNERS
4
5
4
5
6
SECTION
ORIFICE SIZE NATURAL
43
43
43
43
43
ORIFICE SIZE LP
55
55
55
55
55
COMPRESSOR
TYPE
Scroll
Scroll
Scroll
Scroll
Scroll
RATED LOAD AMPS
19.9
19.9
26.4
26.4
26.4
LOCKED ROTOR AMPS
109.0
109.0
134.0
134.0
134.0
CONDENSER
HORSEPOWER
1/4
1/4
1/4
1/4
1/4
FAN MOTOR
RPM
1100
1100
1100
1100
1100
FULL LOAD AMPS
1.4
1.4
1.4
1.4
1.4
LOCKED ROTOR AMPS
2.9
2.9
2.9
2.9
2.9
CONDENSER
BLADE DIAMETER (INCHES)
22
22
22
22
22
FAN
NUMBER OF BLADES
3
3
3
3
3
CFM
3500
3500
3500
3500
3500
CONDENSER
FACE AREA - SQ. FT.
15.3
15.3
11.3
11.3
11.3
COIL
NUMBER OF ROWS
1
1
2
2
2
FINS PER INCH
24
24
27
27
27
EVAPORATOR
HORSEPOWER - NO. OF SPEEDS
3/4 - 5
3/4 - 5
1 - 5
1 - 5
1 - 5
BLOWER
FULL LOAD AMPS
5.8
5.8
7.6
7.6
7.6
MOTOR
LOCKED ROTOR AMPS
--
--
--
--
--
MOTOR SPEED TAP - COOLING
T4
T4
T4
T4
T4
RPM
1050
1050
1050
1050
1050
EVAPORATOR
DIAMETER X WIDTH (INCHES)
11” x 10”
11” x 10”
11” x 10”
11” x 10”
11” x 10”
BLOWER
RATED SCFM COOLING
1550
1550
1750
1750
1750
MAX EXTERNAL STATIC PRESS ("w.c.)
0.5
0.5
0.5
0.5
0.5
EVAPORATOR
FACE AREA - SQ. FT.
5.67
5.67
5.67
5.67
5.67
COIL
NUMBER OF ROWS
4
4
4
4
4
FINS PER INCH
14
14
14
14
14
FILTER SIZE - SQ. FT.
( 2)
5.1
5.1
6.3
6.3
6.3
DRAIN SIZE (INCHES)
3/4
3/4
3/4
3/4
3/4
HEATING
PRIMARY LIMIT SETTING (°F)
170
170
170
170
160
LIMITS
AUXILIARY LIMIT SETTING (°F)
150
150
150
150
150
ROLLOUT LIMIT SETTING (°F)
350
350
350
350
350
GENERAL
PISTON EXPANSION DEVICE
Orifice (.076)
Orifice (.076)
Orifice (.086)
Orifice (.086)
Orifice (.086)
INFORMATION
REFRIGERANT CHARGE R-410A (Oz.)
87
87
91
91
91
POWER SUPPLY ENTRANCE SIZE (INCHES)
1 1/8
1 1/8
1 1/8
1 1/8
1 1/8
LOW VOLTAGE ENTRANCE SIZE (INCHES)
7/8
7/8
7/8
7/8
7/8
SHIPPING WEIGHT LBS.
545
550
555
560
565
OPERATING WEIGHT LBS.
523
528
533
538
543