![background image](http://html1.mh-extra.com/html/daikin/ccxs09pvm/ccxs09pvm_service-manual-removal-procedure_2460457008.webp)
Decoration Panel ASSY
Si091659E
6
Removal Procedure
4
Disconnect each
connector and release
the harnesses.
[S41]: sensor PCB (Room
temperature thermistor)
[S45]: swing motors
[S48]: display/signal receiver
PCB
2. Remove the decoration
cover.
The screw on the right side
runs through the service
cover.
1
2
Remove the 2 screws
of the decoration cover.
Slide the decoration
cover horizontally to
release the 4 hooks.
3
4
Slide the decoration
cover to release the 2
hooks on the left.
Remove the decoration
cover.
3. Remove the display and
control panel.
You can remove the signal
receiver unit without
removing the decoration
panel ASSY.
1
Unfasten the 4 hooks of
the display and control
panel.
Step
Procedure
Points
[S48]
[S45]
[S41]
(R23749)
Hook
Decoration cover
(R23750)
Hook
(R23751)
Hook
Hook
Display and
control panel
(R23752)