![background image](http://html1.mh-extra.com/html/daikin/ccxs09pvm/ccxs09pvm_service-manual-removal-procedure_2460457013.webp)
Si091659E
Air Outlet ASSY
Removal Procedure
11
3
Remove the 2 screws,
and then the swing
motor.
4
Release the link (3).
5
6
Remove the vertical
blades.
Remove the interlock
rod for the vertical
blades.
Step
Procedure
Points
Swing motor
(R23761)
Link (3)
(R23762)
Interlock rod
Vertical blades
(R10927)