![background image](http://html1.mh-extra.com/html/daikin/ccxs09pvm/ccxs09pvm_service-manual-removal-procedure_2460457011.webp)
Si091659E
Air Outlet ASSY
Removal Procedure
9
4. Air Outlet ASSY
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Caution
When reassembling, do not confuse the installing order of the 2 motors for horizontal
blades and the colors of the connectors.
If you set the connectors or motors opposite, the horizontal blades do not move
smoothly or noise may be heard.
Step
Procedure
Points
1. Remove the air outlet
ASSY.
When replacing the air outlet
ASSY, replace the thermal
insulation as well.
1
Remove the thermal
insulation and the 6
screws.
2
Remove the 8 screws
of the air outlet ASSY.
3
Lift the air outlet ASSY
and remove it.
Lift the air outlet ASSY from
the side opposite the swing
motor.
Thermal insulation
(R23757)
Air outlet ASSY
(R23758)
Swing motor
(R10920)