background image

Table of contents

Installation manual

4

FNA25~60A2VEB(9)

Split system air conditioners

4P456958-1J – 2020.12

Table of contents

1 About the documentation

4

1.1

About this document..................................................................

4

2 About the box

4

2.1

Indoor unit .................................................................................

4

2.1.1

To remove the accessories from the indoor unit.........

4

3 About the units and options

5

3.1

System layout ............................................................................

5

4 Preparation

5

4.1

Preparing the installation site ....................................................

5

4.1.1

Installation site requirements of the indoor unit ..........

5

5 Installation

5

5.1

Mounting the indoor unit............................................................

5

5.1.1

Guidelines when installing the indoor unit...................

5

5.1.2

Guidelines when installing the ducting........................

8

5.1.3

Guidelines when installing the drain piping.................

8

5.2

Connecting the refrigerant piping ..............................................

9

5.2.1

To connect the refrigerant piping to the indoor unit ....

9

5.2.2

To check for leaks....................................................... 10

5.3

Connecting the electrical wiring.................................................

10

5.3.1

Specifications of standard wiring components............ 10

5.3.2

To connect the electrical wiring to the indoor unit....... 10

6 Commissioning

11

6.1

Checklist before commissioning ................................................

11

6.2

To perform a test run .................................................................

11

6.3

Error codes when performing a test run ....................................

12

7 Disposal

12

8 Technical data

12

8.1

Wiring diagram ..........................................................................

12

8.1.1

Unified wiring diagram legend..................................... 12

1

About the documentation

1.1

About this document

INFORMATION

Make sure that the user has the printed documentation and
ask him/her to keep it for future reference.

Target audience

Authorised installers

INFORMATION

This appliance is intended to be used by expert or trained
users  in  shops,  in  light  industry,  and  on  farms,  or  for
commercial and household use by lay persons.

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you MUST read before installing

▪ Format: Paper (in the box of the indoor unit)

Indoor unit installation manual:

▪ Installation instructions

▪ Format: Paper (in the box of the indoor unit)

Installer reference guide:

▪ Preparation of the installation, good practices, reference data,…

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.

The original documentation is written in English. All other languages
are translations.

Technical engineering data

▪ A 

subset

  of  the  latest  technical  data  is  available  on  the  regional

Daikin website (publicly accessible).

▪ The 

full  set

  of  latest  technical  data  is  available  on  the  Daikin

Business Portal (authentication required).

2

About the box

2.1

Indoor unit

WARNING: FLAMMABLE MATERIAL

The  R32  refrigerant  (if  applicable)  in  this  unit  is  mildly
flammable.  Refer  to  the  outdoor  unit  specifications  for  the
type of refrigerant to be used.

2.1.1

To remove the accessories from the
indoor unit

24×

e

d

b

a

c

f

g

h

i

j

k

l

m

n

o

a

Installation manual

b

Operation manual

c

General safety precautions

d

Washers for hanger bracket

e

Screws for duct flanges

f

Metal clamp

g

Sealing pads: small and large

h

Drain hose

i

Sealing material

j

Insulation piece: Small (liquid pipe)

k

Insulation piece: Large (gas pipe)

l

Tie wraps

m

Washer fixing plate

n

Air filter

o

Levelling screws

Summary of Contents for Bluevolution FNA35A

Page 1: ...Installation manual Split system air conditioners English Installation manual Split system air conditioners FNA25A2VEB FNA35A2VEB FNA50A2VEB FNA60A2VEB FNA25A2VEB9 FNA35A2VEB9 FNA50A2VEB9 FNA60A2VEB9...

Page 2: ...acestea s fie utilizate n conformitate cu instruc iunile noastre skladni z naslednjimi standardi in drugimi normativi pod pogojem da se uporabljajo v skladu z na imi navodili on vastavuses j rgmis t e...

Page 3: ...cestea s fie utilizate n conformitate cu instruc iunile noastre skladni z naslednjimi standardi in drugimi normativi pod pogojem da se uporabljajo v skladu z na imi navodili on vastavuses j rgmis t e...

Page 4: ...on farms or for commercial and household use by lay persons Documentation set This document is part of a documentation set The complete set consists of General safety precautions Safety instructions...

Page 5: ...conditioner a fire may break out 4 1 1 Installation site requirements of the indoor unit INFORMATION The sound pressure level is less than 70 dBA Use suspension bolts for installation Mind the followi...

Page 6: ...60 m kg Amin m2 1 842 No requirements 1 843 6 2 5 5 1 9 6 4 5 7 2 6 8 6 0 2 1 7 1 6 3 2 2 7 4 6 6 2 3 7 8 6 9 2 4 8 1 7 2 2 5 8 4 7 5 2 6 8 8 7 8 2 7 9 1 8 1 2 8 9 5 8 4 2 9 9 8 8 7 FNA25 35 FNA50 60...

Page 7: ...ng the suction cover B Reattaching the suction cover a Suction cover b Protective grille c Air inlet d Air outlet 7 Remove one leg on the opposite side of the electronic component box 8 Reattach the r...

Page 8: ...n the duct Use the function to adjust the fan rate setting automatically For setting refer to the installation manual of the used user interface The ducting is to be field supplied Air inlet side Atta...

Page 9: ...sory e Drain piping field supply NOTICE Do NOT remove the drain pipe plug Water might leak out Use the drain outlet only to discharge the water if the drain pump is not used or before maintenance Inse...

Page 10: ...applying the bubble test solution to all connections 3 Discharge all nitrogen gas 5 3 Connecting the electrical wiring DANGER RISK OF ELECTROCUTION WARNING ALWAYS use multicore cable for power supply...

Page 11: ...em is properly earthed and the earth terminals are tightened The fuses or locally installed protection devices are installed according to this document and have NOT been bypassed The power supply volt...

Page 12: ...osed The air inlet or air outlet is blocked Error code Possible cause E7 There is a missing phase in case of three phase power supply units Note Operation will be impossible Turn OFF the power recheck...

Page 13: ...M F Fan motor M P Drain pump motor M S Swing motor MR MRCW MRM MRN Magnetic relay N Neutral n N Number of passes through ferrite core PAM Pulse amplitude modulation PCB Printed circuit board PM Power...

Page 14: ......

Page 15: ......