![background image](http://html1.mh-extra.com/html/daikin/altherma-ehfh03s18d-3v-series/altherma-ehfh03s18d-3v-series_installers-reference-manual_4358338094.webp)
9
|
Electrical installation
Installer reference guide
94
E EHFH03S18D
Daikin Altherma 3 R F
4P596806-1C – 2022.09
To prepare stranded conductor wire for installation
Method 1: Twisting conductor
1
Strip insulation (20 mm) from the wires.
2
Slightly twist the end of the conductor to create a "solid-like" connection.
Method 2: Using round crimp-style terminal
1
Strip insulation from wires and slightly twist the end of each wire.
2
Install a round crimp-style terminal on the end of the wire. Place the round
crimp-style terminal on the wire up to the covered part and fasten the
terminal with the appropriate tool.
Use the following methods for installing wires:
Wire type
Installation method
Single-core wire
Or
Stranded conductor wire
twisted to "solid-like"
connection
c b
c
a
a
A
AA´
A´
a
Curled wire (single-core or twisted stranded
conductor wire)
b
Screw
c
Flat washer