![background image](http://html1.mh-extra.com/html/daikin/altherma-ehfh03s18d-3v-series/altherma-ehfh03s18d-3v-series_installers-reference-manual_4358338025.webp)
5
|
About the units and options
Installer reference guide
25
E EHFH03S18D
Daikin Altherma 3 R F
4P596806-1C – 2022.09
5 About the units and options
INFORMATION
This unit is a heating only model. Therefore, all references to cooling in this
document are NOT applicable.
In this chapter
5.1 Identification
5.1.1 Identification label: Outdoor unit
Location
Model identification
Example:
ER L A 03 DA V3
Code
Explanation
ER
European split outdoor pair heat pump
L
Low water temperature – ambient zone (see operation
range)
A
Refrigerant R32
03
Capacity class
DA
Model series
V3
Power supply
5.1.2 Identification label: Indoor unit
Location