14
|
Troubleshooting
Installer reference guide
196
EPGA11~16DAV3(7) + EAVH/23DA6V(7)+9W(7)
Daikin Altherma 3 H F
4P556070-1A – 2021.09
Error code
Detailed error code Description
AA
02
External backup heater
overheated
AH
00
Tank disinfection function
not completed correctly
AJ
03
Too long DHW heat-up time
required
C0
00
Flow sensor malfunction
C0
01
Flow switch malfunction
C0
02
Flow switch malfunction
C4
00
Heat exchanger temperature
sensor problem
C5
00
Heat exchanger thermistor
abnormality
CJ
02
Room temperature sensor
problem
E1
00
OU: PCB defect
E2
00
Leakage current detection
error
E3
00
OU: Actuation of high
pressure switch (HPS)
E4
00
Abnormal suction pressure
E5
00
OU: Overheat of inverter
compressor motor
E6
00
OU: Compressor startup defect
E7
00
OU: Malfunction of outdoor
unit fan motor
E8
00
OU: Power input overvoltage
E9
00
Malfunction of electronic
expansion valve
EA
00
OU: Cool/heat switchover
problem
EC
00
Abnormal increase tank
temperature
EC
04
Tank preheating
F3
00
OU: Malfunction of discharge
pipe temperature
F6
00
OU: Abnormal high pressure in
cooling
FA
00
OU: Abnormal high pressure,
actuation of HPS
H0
00
OU: Voltage/current sensor
problem