7
|
Unit installation
Installer reference guide
85
ERGA04~08EA + EHBH/X04+08EF
Daikin Altherma 3 R W
4P629085-1B – 2021.11
▪
Tilt the top of the unit against the wall at the position of the wall bracket.
▪
Slide the bracket on the back of the unit over the wall bracket. Make sure
the unit is fixed properly.
4
Optional: If you want to fix the unit to the wall from inside the unit:
▪
Remove the upper front panel, and open the switch box. See
75].
▪
Fix the unit to the wall with an Ø8 mm screw.
7.4.4 To connect the drain hose to the drain
Water coming from the pressure relief valve is collected in the drain pan. You must
connect the drain pan to an appropriate drain according to the applicable
legislation.
1
Connect a drain tube (field supply) to the drain pan connector as follows: