![background image](http://html.mh-extra.com/html/daikin/altherma-3-r-w/altherma-3-r-w_installers-reference-manual_501226118.webp)
9
|
Electrical installation
Installer reference guide
118
ERGA04~08EA + EHBH/X04+08EF
Daikin Altherma 3 R W
4P629085-1B – 2021.11
Item
Description
(in case of DHW tank)
Power supply for booster
heater (from indoor unit to
thermal protector of
booster heater)
See:
▪
Installation manual of the DHW tank
▪
Addendum book for optional equipment
Wires: (2+GND)×2.5 mm²
[9.4]
Booster heater
(in case of DHW tank)
Power supply for booster
heater (from mains to
indoor unit)
See:
▪
Installation manual of the domestic hot
water tank
▪
Addendum book for optional equipment
Wires: 2+GND
Maximum running current: 13 A
[9.4]
Booster heater
WLAN module
See:
▪
Installation manual of the WLAN module
▪
Addendum book for optional equipment
▪
Installer reference guide
Use the cable delivered with the WLAN
module.
[D]
Wireless gateway
Bizone kit
See:
▪
Installation manual of the bizone kit
▪
Addendum book for optional equipment
Use the cable delivered with the bizone kit.
[9.P]
Bizone kit
for room thermostat (wired or wireless):
In case of…
See…
Wireless room thermostat
▪
Installation manual of the wireless room
thermostat
▪
Addendum book for optional equipment
Wired room thermostat
without multi-zoning base unit
▪
Installation manual of the wired room
thermostat
▪
Addendum book for optional equipment