3/12
Breadcrumb Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
2.D.1
[F-0B]
R/W
0: No
1: Yes
2.D.2
[F-0C]
R/W
0: No
1: Yes (*3)
Main zone
2.E
R/W
0: 2-points
1: Slope-Offset
Additional zone
3.4
0: Fixed
1: WD heating, fixed cooling (*3)
2: Weather dependent
└─
Heating WD curve
3.5
[0-00]
R/W
[9-05]~min(45,[9-06])°C, step: 1°C
25°C
3.5
[0-01]
R/W
[9-05]~[9-06]°C, step: 1°C
[2-0C]=0
40°C
[2-0C]=1
45°C
[2-0C]=2
55°C
3.5
[0-02]
R/W
10~25°C, step: 1°C
15°C
3.5
[0-03]
R/W
-40~5°C, step: 1°C
-10°C
└─
Cooling WD curve
3.6
[0-04]
R/W
[9-07]~[9-08]°C, step: 1°C
[2-0C]=0:
18°C (*3)
[2-0C]=1:
7°C (*3)
[2-0C]=2:
18°C (*3)
3.6
[0-05]
R/W
[9-07]~[9-08]°C, step: 1°C
22°C (*3)
3.6
[0-06]
R/W
25~43°C, step: 1°C
35°C (*3)
3.6
[0-07]
R/W
10~25°C, step: 1°C
20°C (*3)
Additional zone
3.7
[2-0D]
R/O
0: Underfloor heating
1: Fancoil unit
2: Radiator
└─
Setpoint range
3.8.1
[9-05]
R/W
15~37°C, step: 1°C
25°C
3.8.2
[9-06]
R/W
37~65, step: 1°C
[2-0C]=2:
65°C
[2-0C]
≠
2:
55°C
3.8.3
[9-07]
R/W
5~18°C, step: 1°C
7°C (*3)
3.8.4
[9-08]
R/W
18~22°C, step: 1°C
22°C (*3)
Additional zone
3.A
[C-06]
R/W
1: 1 contact
2: 2 contacts
└─
Delta T
3.B.1
[1-0C]
R/W
3~12°C, step: 1°C
[2-0C]
≠
2 (Radiator)
5°C
[2-0C] = 2 (Radiator)
10°C
3.B.2
[1-0E]
R/W
3~10°C, step: 1°C
5°C (*3)
Additional zone
3.C
R/O
0: 2-points
1: Slope-Offset
Space heating / cooling
└─
Operation range
4.3.1
[4-02]
R/W
14~35°C, step: 1°C
35°C
4.3.2
[F-01]
R/W
10~35°C, step: 1°C
20°C (*3)
Space heating / cooling
4.4
[7-02]
R/W
0: Single zone
1: Dual zone
4.5
[F-0D]
R/W
0: Continuous
1: Sample
2: Request
4.6
[E-02]
R/W (*3)
R/O
0: Reversible (*3)
1: Heating only
└─
Pump limitation
4.8.1
[9-0E]
R/W
0~8, step:1
0: No limitation
1~4: 90~60% pump speed
5~8: 90-60% pump speed during
sampling
6
4.8.2
[9-0D]
R/W
0~8, step:1
0: No limitation
1~4: 90~60% pump speed
5~8: 90-60% pump speed during
sampling
6
Space cooling OFF temp
Number of zones
Pump operation mode
Unit type
Main zone
Additional zone
Cooling maximum
Ext Thermostat type
Delta T heating
Delta T cooling
WD curve type
Space heating OFF temp
High ambient temp. for LWT add zone cooling WD curve.
Low ambient temp. for LWT add zone cooling WD curve.
Emitter type
Heating minimum
Heating maximum
Cooling minimum
Leaving water value for high ambient temp. for LWT add zone heating WD curve.
Leaving water value for low ambient temp. for LWT add zone heating WD curve.
High ambient temp. for LWT add zone heating WD curve.
Low ambient temp. for LWT add zone heating WD curve.
Leaving water value for high ambient temp. for LWT add zone cooling WD curve.
Leaving water value for low ambient temp. for LWT add zone cooling WD curve.
During thermo
During cooling
WD curve type
Setpoint mode
(*1)
*6V*_(*2)
*9W*_
(*3)
Only
applicable
for
models
where
cooling
is
possible
4P717810
‐
1
‐
2022.11