11
|
Configuration
Installer reference guide
213
ERRA08~12E + EL23E
Daikin Altherma 3 R MT F
4P708478-1 – 2023.05
Possible read-out information
In menu…
You can read out…
[8.1]
Energy data
Produced energy, consumed electricity,
and consumed gas
[8.2]
Malfunction history
Malfunction history
[8.3]
Dealer information
Contact/helpdesk number
[8.4]
Sensors
Room temperature, outside
temperature, leaving water
temperature,…
[8.5]
Actuators
Status/mode of each actuator
Example:
Unit pump ON/OFF
[8.6]
Operation modes
Current operation mode
Example:
Defrost/oil return mode
[8.7]
About
Version information about the system
[8.8]
Connection status
Information about the connection
status of the unit, the room thermostat,
the Lan adapter and WLAN.
[8.9]
Running hours
Running hours of specific system
components
11.6.9 Installer settings
Overview
The following items are listed in the submenu:
9
Installer settings
Commissioning
Information
User settings
User profile
[9]
Installer settings
[9.1]
Configuration wizard
[9.2]
Domestic hot water
[9.3]
Backup heater
[9.5]
Emergency
[9.6]
Balancing
[9.7]
Water pipe freeze prevention
[9.8]
Benefit kWh power supply
[9.9]
Power consumption control
[9.A]
Energy metering
[9.B]
Sensors
[9.C]
Bivalent
[9.D]
Alarm output
[9.E]
Auto restart
[9.F]
Power saving function
[9.G]
Disable protections
[9.H]
Forced defrost
[9.I]
Overview field settings
[9.N]
Export MMI settings