5 Operation

Operation manual

9

EBSH/X(B)11+16P30+50DF
Daikin Altherma 3 R ECH

O

4P663485-1 – 2021.07

5.3

Possible screens: Overview

The most common screens are as follows:

+

a

OR

b

c

c2

c4

c1

c3

a

Home screen

b

Main menu screen

c

Lower level screens:

c1

: Setpoint screen

c2

: Detailed screen with values

c3

: Screen with weather-dependent curve

c4

: Screen with schedule

5.3.1

Home screen

Press  the 

  button  to  go  back  to  the  home  screen.  You  see  an

overview  of  the  unit  configuration  and  the  room  and  setpoint
temperatures.  Only  symbols  applicable  for  your  configuration  are
visible on the home screen.

6

1.6

bar

26 Feb 2019

22:19

55

21
35

j

e2

l

k1
k2

k3

45

d

e1

g3

g2

h1

g1

f

i2 i3

i4

h2

i1

a2

a1

e3

b c

Possible actions on this screen

Go through the list of the main menu.

Go to the main menu screen.

Enable/disable breadcrumbs.

Item

Description

a Domestic hot water

a1

Domestic hot water

a2

55

Measured tank temperature

(a)

Item

Description

b Disinfection / Powerful

Disinfection mode active

Powerful operation mode active

c Emergency

Heat pump failure and system operates in

Emergency

 mode or heat pump is forced off.

d Current date and time

e Smart energy

e1

Smart energy is available via solar panels or smart
grid.

e2

Smart energy is currently being used for space
heating.

e3

Smart energy is currently being used for domestic
hot water.

f

Space operation mode

Cooling

Heating

g Outdoor / quiet mode

g1

6

Measured outdoor temperature

(a)

g2

Quiet mode active

g3

Outdoor unit

h Indoor unit / domestic hot water tank

h1

Floor-standing indoor unit with integrated tank

Wall-mounted indoor unit

Wall-mounted indoor unit with separated tank

h2

Water pressure

i

Main zone

i1

Installed room thermostat type:

Unit operation is decided based on the ambient
temperature of the dedicated Human Comfort
Interface (BRC1HHDA used as room thermostat).

Unit operation is decided by the external room
thermostat (wired or wireless).

No room thermostat installed or set. Unit operation
is decided based on the leaving water temperature
regardless of the actual room temperature and/or
heating demand of the room.

i2

Installed heat emitter type:

Underfloor heating

Fancoil unit

Radiator

i3

21

Measured room temperature

(a)

i4

35

Leaving water temperature setpoint

(a)

j

Holiday mode

Holiday mode active

Summary of Contents for Altherma 3 R ECH2O

Page 1: ...ish Operation manual Daikin Altherma 3 R ECH O EBSH11P30DF EBSHB11P30DF EBSH11P50DF EBSHB11P50DF EBSH16P30DF EBSHB16P30DF EBSH16P50DF EBSHB16P50DF EBSX11P30DF EBSXB11P30DF EBSX11P50DF EBSXB11P50DF EBS...

Page 2: ...20 11 1 Configuration wizard 20 11 2 Settings menu 20 1 About this document Thank you for purchasing this product Please Read the documentation carefully before operating the user interface to ensure...

Page 3: ...Cleaning and user maintenance SHALL NOT be made by children without supervision WARNING To prevent electrical shocks or fire Do NOT rinse the unit Do NOT operate the unit with wet hands Do NOT place...

Page 4: ...Before you purge air from heat emitters or collectors check if or is displayed on the home screen of the user interface If not you can purge air immediately If yes make sure that the room where you w...

Page 5: ...external room thermostat control the protection is NOT guaranteed 1 Go to C 2 Operation Space heating cooling Operation Space heating cooling Tank Off On C 2 2 Set operation to On or Off To change the...

Page 6: ...e temperatures Change the temperature Go to the next temperature Confirm changes and proceed More information For more information see also 5 4 Turning operation ON or OFF 411 5 6 Space heating coolin...

Page 7: ...rect config file on the USB memory stick Export the current settings i e field settings MMI EEPROM settings schedule timers from the user interface MMI to the USB memory stick LCD screen The LCD scree...

Page 8: ...ylight savings time Format 7 3 Holiday Activation From Till 7 4 Quiet Activation Schedule Level 7 5 Electricity price High Medium Low Schedule 5 Tank Powerful operation Schedule 1 9 Room comfort setpo...

Page 9: ...mp failure and system operates in Emergency mode or heat pump is forced off d Current date and time e Smart energy e1 Smart energy is available via solar panels or smart grid e2 Smart energy is curren...

Page 10: ...ure 2 Main zone Shows the applicable symbol for your main zone emitter type Set the leaving water temperature for the main zone 3 Additional zone Restriction Only displayed if there are two leaving wa...

Page 11: ...ting cooling operation OFF Tank heating operation 55 21 35 45 c 55 21 35 45 d c Tank heating operation ON d Tank heating operation OFF 5 4 2 To turn ON or OFF Space heating cooling operation NOTICE Ro...

Page 12: ...lowing options Heating Only heating mode Cooling Only cooling mode Automatic The operation mode changes automatically between heating and cooling based on the outdoor temperature Restricted per month...

Page 13: ...day With the higher set temperature in the afternoon and evening more hot water is available During the morning you consume hot water and the storage tank temperature decreases When the tank temperat...

Page 14: ...the name of the current schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 2 Select Delete Delete Rename Select 3 Select OK to confirm To clear the content of a day schedule 1 Select the day of whic...

Page 15: ...Weather dependent curve 5 9 1 What is a weather dependent curve Weather dependent operation The unit operates weather dependent if the desired leaving water or tank temperature is determined automati...

Page 16: ...ambient temperatures For example if leaving water temperature is in general fine but at low ambient temperatures too cold raise the slope so that leaving water temperature is heated increasingly more...

Page 17: ...e tank When the maximum or minimum setpoint is reached the curve flattens out To fine tune the weather dependent curve slope offset curve The following table describes how to fine tune the weather dep...

Page 18: ...es example open flames an operating gas appliance or an operating electric heater WARNING Do NOT pierce or burn refrigerant cycle parts Do NOT use cleaning materials or means to accelerate the defrost...

Page 19: ...o the Malfunctioning main menu screen and confirm whether the backup heater can take over the heat load or not Alternatively when Emergency is set to auto SH reduced DHW on space heating is reduced bu...

Page 20: ...tings Tables to be filled in by installer 11 1 Configuration wizard Setting Fill in System Indoor unit type read only Backup heater type 9 3 1 Domestic hot water 9 2 1 Emergency 9 5 Number of zones 4...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...4P663485 1 2021 07 Copyright 2021 Daikin 4P663485 1 0000000U Verantwortung f r Energie und Umwelt...

Reviews: