background image

5 Operation

Operation manual

10

EBSH/X(B)11+16P30+50DF

Daikin Altherma 3 R ECH

O

4P663485-1 – 2021.07

Item

Description

k Additional zone

k1

Installed room thermostat type:

Unit operation is decided by the external room
thermostat (wired or wireless).

No room thermostat installed or set. Unit operation
is decided based on the leaving water temperature
regardless of the actual room temperature and/or
heating demand of the room.

k2

Installed heat emitter type:

Underfloor heating

Fancoil unit

Radiator

k3

45

Leaving water temperature setpoint

(a)

l

Malfunction

A malfunction occurred.

See 

"8.1 To display the help text in case of a

malfunction"

 [

4

 18] for more information.

(a)

If the corresponding operation (for example: space heating) is not
active, the circle is greyed out.

5.3.2

Main menu screen

Starting from the home screen, press (

) or turn (

) the

left  dial  to  open  the  main  menu  screen.  From  the  main  menu,  you
can access the different setpoint screens and submenus.

a

2

Main zone

Additional zone

Room

Malfunctioning

Space heating/cooling

a

Selected submenu

Possible actions on this screen

Go through the list.

Enter the submenu.

Enable/disable breadcrumbs.

Submenu

Description

[0]

 or 

Malfunctioning

Restriction: 

Only displayed if a

malfunction occurs.

See 

"8.1 To display the help text in

case of a malfunction"

 [

4

 18] for more

information.

[1]

 

Room

Restriction: 

Only displayed if a

dedicated Human Comfort Interface
(BRC1HHDA used as room
thermostat) is controlling the indoor
unit.

Set the room temperature.

[2]

 

Main zone

Shows the applicable symbol for your
main zone emitter type.

Set the leaving water temperature for
the main zone.

[3]

 

Additional zone

Restriction: 

Only displayed if there

are two leaving water temperature
zones. Shows the applicable symbol
for your additional zone emitter type.

Set the leaving water temperature for
the additional zone (if present).

Submenu

Description

[4]

 

Space heating/

cooling

Shows the applicable symbol of your
unit.

Put the unit in heating mode or cooling
mode. You cannot change the mode
on heating only models.

[5]

 

Tank

Set the storage tank temperature.

[7]

 

User settings

Gives access to user settings such as
holiday mode and quiet mode.

[8]

 

Information

Displays data and information about
the indoor unit.

[9]

 

Installer

settings

Restriction: 

Only for the installer.

Gives access to advanced settings.

[A]

 

Commissioning

Restriction: 

Only for the installer.

Perform tests and maintenance.

[B]

 

User profile

Change the active user profile.

[C]

 

Operation

Turn heating/cooling functionality and
domestic hot water preparation on or
off.

[D]

 

Wireless

gateway

Restriction: 

Only displayed if a

wireless LAN (WLAN) is installed.

Contains settings needed when
configuring the Daikin Residential
Controller app.

5.3.3

Setpoint screen

The  setpoint  screen  is  displayed  for  screens  describing  system
components that need a setpoint value.

Examples

[1] Room temperature screen

+

21

°C

1

Room

[2] Main zone screen

+

35

°C

2

Main zone

[3] Additional zone screen

+

45

°C

3

Additional zone

[5] Tank temperature screen

+

50

°C

5

Tank

Explanation

a1

d

+

d

e

d

e

c

a2

b1

b2

Possible actions on this screen

Go through the list of the submenu.

Go to the submenu.

Adjust and automatically apply the desired
temperature.

Summary of Contents for Altherma 3 R ECH2O

Page 1: ...ish Operation manual Daikin Altherma 3 R ECH O EBSH11P30DF EBSHB11P30DF EBSH11P50DF EBSHB11P50DF EBSH16P30DF EBSHB16P30DF EBSH16P50DF EBSHB16P50DF EBSX11P30DF EBSXB11P30DF EBSX11P50DF EBSXB11P50DF EBS...

Page 2: ...20 11 1 Configuration wizard 20 11 2 Settings menu 20 1 About this document Thank you for purchasing this product Please Read the documentation carefully before operating the user interface to ensure...

Page 3: ...Cleaning and user maintenance SHALL NOT be made by children without supervision WARNING To prevent electrical shocks or fire Do NOT rinse the unit Do NOT operate the unit with wet hands Do NOT place...

Page 4: ...Before you purge air from heat emitters or collectors check if or is displayed on the home screen of the user interface If not you can purge air immediately If yes make sure that the room where you w...

Page 5: ...external room thermostat control the protection is NOT guaranteed 1 Go to C 2 Operation Space heating cooling Operation Space heating cooling Tank Off On C 2 2 Set operation to On or Off To change the...

Page 6: ...e temperatures Change the temperature Go to the next temperature Confirm changes and proceed More information For more information see also 5 4 Turning operation ON or OFF 411 5 6 Space heating coolin...

Page 7: ...rect config file on the USB memory stick Export the current settings i e field settings MMI EEPROM settings schedule timers from the user interface MMI to the USB memory stick LCD screen The LCD scree...

Page 8: ...ylight savings time Format 7 3 Holiday Activation From Till 7 4 Quiet Activation Schedule Level 7 5 Electricity price High Medium Low Schedule 5 Tank Powerful operation Schedule 1 9 Room comfort setpo...

Page 9: ...mp failure and system operates in Emergency mode or heat pump is forced off d Current date and time e Smart energy e1 Smart energy is available via solar panels or smart grid e2 Smart energy is curren...

Page 10: ...ure 2 Main zone Shows the applicable symbol for your main zone emitter type Set the leaving water temperature for the main zone 3 Additional zone Restriction Only displayed if there are two leaving wa...

Page 11: ...ting cooling operation OFF Tank heating operation 55 21 35 45 c 55 21 35 45 d c Tank heating operation ON d Tank heating operation OFF 5 4 2 To turn ON or OFF Space heating cooling operation NOTICE Ro...

Page 12: ...lowing options Heating Only heating mode Cooling Only cooling mode Automatic The operation mode changes automatically between heating and cooling based on the outdoor temperature Restricted per month...

Page 13: ...day With the higher set temperature in the afternoon and evening more hot water is available During the morning you consume hot water and the storage tank temperature decreases When the tank temperat...

Page 14: ...the name of the current schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 2 Select Delete Delete Rename Select 3 Select OK to confirm To clear the content of a day schedule 1 Select the day of whic...

Page 15: ...Weather dependent curve 5 9 1 What is a weather dependent curve Weather dependent operation The unit operates weather dependent if the desired leaving water or tank temperature is determined automati...

Page 16: ...ambient temperatures For example if leaving water temperature is in general fine but at low ambient temperatures too cold raise the slope so that leaving water temperature is heated increasingly more...

Page 17: ...e tank When the maximum or minimum setpoint is reached the curve flattens out To fine tune the weather dependent curve slope offset curve The following table describes how to fine tune the weather dep...

Page 18: ...es example open flames an operating gas appliance or an operating electric heater WARNING Do NOT pierce or burn refrigerant cycle parts Do NOT use cleaning materials or means to accelerate the defrost...

Page 19: ...o the Malfunctioning main menu screen and confirm whether the backup heater can take over the heat load or not Alternatively when Emergency is set to auto SH reduced DHW on space heating is reduced bu...

Page 20: ...tings Tables to be filled in by installer 11 1 Configuration wizard Setting Fill in System Indoor unit type read only Backup heater type 9 3 1 Domestic hot water 9 2 1 Emergency 9 5 Number of zones 4...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...4P663485 1 2021 07 Copyright 2021 Daikin 4P663485 1 0000000U Verantwortung f r Energie und Umwelt...

Reviews: