2 User safety instructions

Operation manual

3

EBSH/X(B)11+16P30+50DF
Daikin Altherma 3 R ECH

O

4P663485-1 – 2021.07

Breadcrumbs

Breadcrumbs  (example: 

[4.3]

)  help  you  to  locate  where  you  are  in

the menu structure of the user interface.

1

To 

enable

 the breadcrumbs: In the home screen or

main menu screen, press the help button. The
breadcrumbs appear in the top left corner of the
screen.

2

To 

disable

 the breadcrumbs: Press the help button

again.

This document also mentions these breadcrumbs. 

Example:

1

Go to 

[4.3]

Space heating/cooling

 > 

Operation

range

.

This means:

1

Starting from the home screen, turn the left dial and
go to 

Space heating/cooling

.

4

Space heating/cooling

2

Press the left dial to enter the submenu.

3

Turn the left dial and go to 

Operation range

.

Operation range

4.3

4

Press the left dial to enter the submenu.

2

User safety instructions

Always observe the following safety instructions and regulations.

2.1

General

WARNING

If you are NOT sure how to operate the
unit, contact your installer.

WARNING

This appliance can be used by children
aged from 8 years and above and
persons with reduced physical, sensory
or mental capabilities or lack of
experience and knowledge if they have
been given supervision or instruction

concerning use of the appliance in a
safe way and understand the hazards
involved.

Children SHALL NOT play with the
appliance.

Cleaning and user maintenance
SHALL NOT be made by children
without supervision.

WARNING

To prevent electrical shocks or fire:

▪ Do NOT rinse the unit.

▪ Do NOT operate the unit with wet

hands.

▪ Do NOT place any objects containing

water on the unit.

CAUTION

▪ Do NOT place any objects or

equipment on top of the unit.

▪ Do NOT sit, climb or stand on the

unit.

▪ Units are marked with the following symbol:

This  means  that  electrical  and  electronic  products  may  NOT  be
mixed  with  unsorted  household  waste.  Do  NOT  try  to  dismantle
the  system  yourself:  the  dismantling  of  the  system,  treatment  of
the  refrigerant,  of  oil  and  of  other  parts  MUST  be  done  by  an
authorised installer and MUST comply with applicable legislation.

Units MUST be treated at a specialised treatment facility for reuse,
recycling  and  recovery.  By  ensuring  this  product  is  disposed  of
correctly, you will help to prevent potential negative consequences
for  the  environment  and  human  health.  For  more  information,
contact your installer or local authority.

▪ Batteries are marked with the following symbol:

This  means  that  the  batteries  may  NOT  be  mixed  with  unsorted
household  waste.  If  a  chemical  symbol  is  printed  beneath  the
symbol,  this  chemical  symbol  means  that  the  battery  contains  a
heavy metal above a certain concentration.

Possible chemical symbols are: Pb: lead (>0.004%).

Waste  batteries  MUST  be  treated  at  a  specialised  treatment
facility  for  reuse.  By  ensuring  waste  batteries  are  disposed  of
correctly, you will help to prevent potential negative consequences
for the environment and human health.

Summary of Contents for Altherma 3 R ECH2O

Page 1: ...ish Operation manual Daikin Altherma 3 R ECH O EBSH11P30DF EBSHB11P30DF EBSH11P50DF EBSHB11P50DF EBSH16P30DF EBSHB16P30DF EBSH16P50DF EBSHB16P50DF EBSX11P30DF EBSXB11P30DF EBSX11P50DF EBSXB11P50DF EBS...

Page 2: ...20 11 1 Configuration wizard 20 11 2 Settings menu 20 1 About this document Thank you for purchasing this product Please Read the documentation carefully before operating the user interface to ensure...

Page 3: ...Cleaning and user maintenance SHALL NOT be made by children without supervision WARNING To prevent electrical shocks or fire Do NOT rinse the unit Do NOT operate the unit with wet hands Do NOT place...

Page 4: ...Before you purge air from heat emitters or collectors check if or is displayed on the home screen of the user interface If not you can purge air immediately If yes make sure that the room where you w...

Page 5: ...external room thermostat control the protection is NOT guaranteed 1 Go to C 2 Operation Space heating cooling Operation Space heating cooling Tank Off On C 2 2 Set operation to On or Off To change the...

Page 6: ...e temperatures Change the temperature Go to the next temperature Confirm changes and proceed More information For more information see also 5 4 Turning operation ON or OFF 411 5 6 Space heating coolin...

Page 7: ...rect config file on the USB memory stick Export the current settings i e field settings MMI EEPROM settings schedule timers from the user interface MMI to the USB memory stick LCD screen The LCD scree...

Page 8: ...ylight savings time Format 7 3 Holiday Activation From Till 7 4 Quiet Activation Schedule Level 7 5 Electricity price High Medium Low Schedule 5 Tank Powerful operation Schedule 1 9 Room comfort setpo...

Page 9: ...mp failure and system operates in Emergency mode or heat pump is forced off d Current date and time e Smart energy e1 Smart energy is available via solar panels or smart grid e2 Smart energy is curren...

Page 10: ...ure 2 Main zone Shows the applicable symbol for your main zone emitter type Set the leaving water temperature for the main zone 3 Additional zone Restriction Only displayed if there are two leaving wa...

Page 11: ...ting cooling operation OFF Tank heating operation 55 21 35 45 c 55 21 35 45 d c Tank heating operation ON d Tank heating operation OFF 5 4 2 To turn ON or OFF Space heating cooling operation NOTICE Ro...

Page 12: ...lowing options Heating Only heating mode Cooling Only cooling mode Automatic The operation mode changes automatically between heating and cooling based on the outdoor temperature Restricted per month...

Page 13: ...day With the higher set temperature in the afternoon and evening more hot water is available During the morning you consume hot water and the storage tank temperature decreases When the tank temperat...

Page 14: ...the name of the current schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 2 Select Delete Delete Rename Select 3 Select OK to confirm To clear the content of a day schedule 1 Select the day of whic...

Page 15: ...Weather dependent curve 5 9 1 What is a weather dependent curve Weather dependent operation The unit operates weather dependent if the desired leaving water or tank temperature is determined automati...

Page 16: ...ambient temperatures For example if leaving water temperature is in general fine but at low ambient temperatures too cold raise the slope so that leaving water temperature is heated increasingly more...

Page 17: ...e tank When the maximum or minimum setpoint is reached the curve flattens out To fine tune the weather dependent curve slope offset curve The following table describes how to fine tune the weather dep...

Page 18: ...es example open flames an operating gas appliance or an operating electric heater WARNING Do NOT pierce or burn refrigerant cycle parts Do NOT use cleaning materials or means to accelerate the defrost...

Page 19: ...o the Malfunctioning main menu screen and confirm whether the backup heater can take over the heat load or not Alternatively when Emergency is set to auto SH reduced DHW on space heating is reduced bu...

Page 20: ...tings Tables to be filled in by installer 11 1 Configuration wizard Setting Fill in System Indoor unit type read only Backup heater type 9 3 1 Domestic hot water 9 2 1 Emergency 9 5 Number of zones 4...