5 Operation

Operation manual

6

EBSH/X(B)11+16P30+50DF

Daikin Altherma 3 R ECH

O

4P663485-1 – 2021.07

Zone

Go to …

Main zone – Cooling

[2.6] 

Main zone

 > 

Cooling WD

curve

Additional zone – Heating

[3.5] 

Additional zone

 >

Heating WD curve

Additional zone – Cooling

[3.6] 

Additional zone

 >

Cooling WD curve

2

Change the weather-dependent curve.

There are 2 types of WD curves: 

slope-offset curve

 (default),

and 

2-points  curve

.  If  needed,  you  can  change  the  type  in

[2.E] 

Main  zone

  > 

WD  curve  type

.  The  way  to  adjust  the

curve depends on the type.

Slope-offset curve

Slope. 

When slope is changed,

the new preferred temperature at
X1 is unequally higher than the
preferred temperature at X2.

X1

X2

c

d

Y1

Y2

Y3

Y4

a

b

Offset

. When offset is changed,

the new preferred temperature at
X1 is equally higher as the
preferred temperature at X2.

Y1

Y2

Y3

Y4

X1

X2

a

b

c

d

X1, X2

Outdoor ambient temperature

Y1~Y4

Desired leaving water temperature

a

WD curve before changes

b

WD curve after changes

c

Slope

d

Offset

Possible actions on this screen

Select slope or offset.

Increase or decrease the slope/offset.

When slope is selected: set slope and go to offset.

When offset is selected: set offset.

Confirm changes and return to the submenu.

2-points curve

Y1

Y2

X1

X2

X1, X2

Outdoor ambient temperature

Y1, Y2

Desired leaving water temperature

Possible actions on this screen

Go through the temperatures.

Change the temperature.

Go to the next temperature.

Confirm changes and proceed.

More information

For more information, see also:

"5.4 Turning operation ON or OFF"

 [

4

 11]

"5.6 Space heating/cooling control"

 [

4

 12]

"5.8 Schedule screen: Example"

 [

4

 14]

"5.9 Weather-dependent curve"

 [

4

 15]

▪ User reference guide

4.3

Domestic hot water

To turn tank heating operation ON or OFF

NOTICE

To  ensure  safe  operation  of  the  system,  do  NOT  turn  off
DHW when space heating is required.

NOTICE

Disinfection  mode

.  Even  if  you  turn  OFF  tank  heating

operation ([C.3]: 

Operation

 > 

Tank

), disinfection mode will

remain  active.  However,  if  you  turn  it  OFF  while
disinfection is running, an AH error occurs.

1

Go to [C.3]: 

Operation

 > 

Tank

.

Operation

Tank

Off

On

Space heating/cooling

C.3

2

Set operation to 

On

 or 

Off

.

To change the tank temperature setpoint

In 

Reheat  only

  mode,  you  can  use  the  tank  temperature  setpoint

screen  to  read  out  and  adjust  the  storage  tank  temperature.  The
resulting  domestic  hot  water  temperature  depends  on  this  setpoint
as well as the actual storage tank temperature.

1

Go to [5]: 

Tank

.

Tank

5

2

Adjust the domestic hot water temperature.

+

50

°C

5

a

b

Tank

a

 Actual domestic hot water temperature

b

 Desired domestic hot water temperature

In other modes, you can only view the setpoint screen but not modify
it.

More information

For more information, see also:

"5.4 Turning operation ON or OFF"

 [

4

 11]

"5.7 Domestic hot water control"

 [

4

 13]

"5.8 Schedule screen: Example"

 [

4

 14]

▪ User reference guide

5

Operation

INFORMATION

Cooling is only applicable in case of reversible models.

Summary of Contents for Altherma 3 R ECH2O

Page 1: ...ish Operation manual Daikin Altherma 3 R ECH O EBSH11P30DF EBSHB11P30DF EBSH11P50DF EBSHB11P50DF EBSH16P30DF EBSHB16P30DF EBSH16P50DF EBSHB16P50DF EBSX11P30DF EBSXB11P30DF EBSX11P50DF EBSXB11P50DF EBS...

Page 2: ...20 11 1 Configuration wizard 20 11 2 Settings menu 20 1 About this document Thank you for purchasing this product Please Read the documentation carefully before operating the user interface to ensure...

Page 3: ...Cleaning and user maintenance SHALL NOT be made by children without supervision WARNING To prevent electrical shocks or fire Do NOT rinse the unit Do NOT operate the unit with wet hands Do NOT place...

Page 4: ...Before you purge air from heat emitters or collectors check if or is displayed on the home screen of the user interface If not you can purge air immediately If yes make sure that the room where you w...

Page 5: ...external room thermostat control the protection is NOT guaranteed 1 Go to C 2 Operation Space heating cooling Operation Space heating cooling Tank Off On C 2 2 Set operation to On or Off To change the...

Page 6: ...e temperatures Change the temperature Go to the next temperature Confirm changes and proceed More information For more information see also 5 4 Turning operation ON or OFF 411 5 6 Space heating coolin...

Page 7: ...rect config file on the USB memory stick Export the current settings i e field settings MMI EEPROM settings schedule timers from the user interface MMI to the USB memory stick LCD screen The LCD scree...

Page 8: ...ylight savings time Format 7 3 Holiday Activation From Till 7 4 Quiet Activation Schedule Level 7 5 Electricity price High Medium Low Schedule 5 Tank Powerful operation Schedule 1 9 Room comfort setpo...

Page 9: ...mp failure and system operates in Emergency mode or heat pump is forced off d Current date and time e Smart energy e1 Smart energy is available via solar panels or smart grid e2 Smart energy is curren...

Page 10: ...ure 2 Main zone Shows the applicable symbol for your main zone emitter type Set the leaving water temperature for the main zone 3 Additional zone Restriction Only displayed if there are two leaving wa...

Page 11: ...ting cooling operation OFF Tank heating operation 55 21 35 45 c 55 21 35 45 d c Tank heating operation ON d Tank heating operation OFF 5 4 2 To turn ON or OFF Space heating cooling operation NOTICE Ro...

Page 12: ...lowing options Heating Only heating mode Cooling Only cooling mode Automatic The operation mode changes automatically between heating and cooling based on the outdoor temperature Restricted per month...

Page 13: ...day With the higher set temperature in the afternoon and evening more hot water is available During the morning you consume hot water and the storage tank temperature decreases When the tank temperat...

Page 14: ...the name of the current schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 2 Select Delete Delete Rename Select 3 Select OK to confirm To clear the content of a day schedule 1 Select the day of whic...

Page 15: ...Weather dependent curve 5 9 1 What is a weather dependent curve Weather dependent operation The unit operates weather dependent if the desired leaving water or tank temperature is determined automati...

Page 16: ...ambient temperatures For example if leaving water temperature is in general fine but at low ambient temperatures too cold raise the slope so that leaving water temperature is heated increasingly more...

Page 17: ...e tank When the maximum or minimum setpoint is reached the curve flattens out To fine tune the weather dependent curve slope offset curve The following table describes how to fine tune the weather dep...

Page 18: ...es example open flames an operating gas appliance or an operating electric heater WARNING Do NOT pierce or burn refrigerant cycle parts Do NOT use cleaning materials or means to accelerate the defrost...

Page 19: ...o the Malfunctioning main menu screen and confirm whether the backup heater can take over the heat load or not Alternatively when Emergency is set to auto SH reduced DHW on space heating is reduced bu...

Page 20: ...tings Tables to be filled in by installer 11 1 Configuration wizard Setting Fill in System Indoor unit type read only Backup heater type 9 3 1 Domestic hot water 9 2 1 Emergency 9 5 Number of zones 4...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...4P663485 1 2021 07 Copyright 2021 Daikin 4P663485 1 0000000U Verantwortung f r Energie und Umwelt...

Reviews: