Unit installation
Installer reference guide
70
EPRA08~W1 + ETSH/X(B)12P30+50EF
Daikin Altherma 3 H MT ECH₂O
4P663478-1 – 2021.07
Maximum total water piping length between indoor unit and
outdoor unit when using 1 1/4" piping
50 m
(a)
(single
run)
(a)
Precise water piping length can be determined using the Hydronic Piping Calculation tool.
The Hydronic Piping Calculation tool is part of the Heating Solutions Navigator which can
be reached via
https://professional.standbyme.daikin.eu
. Please contact your dealer if you
have no access to Heating Solutions Navigator.
▪
Mind the following spacing installation guidelines:
CAUTION
Install the indoor unit at a minimum distance of 1 m from other heat sources (>80°C)
(e.g. electrical heater, oil heater, chimney) and combustible materials. Otherwise the
unit may be damaged or in extreme cases catch fire.
≥500
00
1≥
≥100
08
4≥
[
]
mm
a
b
a
≥100
a+b
≥600
b
≥300
INFORMATION
If you have limited installation space, do the following before installing the unit in its
final position:
"7.4.4 To connect the drain hose to the drain"
▪
The foundation must be strong enough to bear the weight of the unit. Take the
weight of the unit with a storage tank full of water into account.
Make sure, in the event of a water leak, water cannot cause any damage to the
installation space and surroundings.
▪
The foundation must be level and smooth.
Do NOT install the unit in places such as:
▪
In places where a mineral oil mist, spray or vapour may be present in the
atmosphere. Plastic parts may deteriorate and fall off or cause water leakage.
▪
Sound sensitive areas (e.g. near a bedroom), so that the operation noise will
cause no trouble.
▪
In places with high humidity (max. RH=85%), for example a bathroom.
▪
In places where frost is possible. Ambient temperature around the indoor unit
must be >5°C.
▪
In places where the unit is exposed to direct sunlight for long periods of time.
Extensive UV radiation can damage the unit.
7.2 Opening and closing the units
7.2.1 About opening the units
At certain times, you have to open the unit.
Example:
▪
When connecting the electrical wiring
Summary of Contents for Altherma 3 H MT ECH2O