3 Operation

Operation manual

8

EABH/9W + EAVH/X16S(U)18+9W

Daikin Altherma 3 H F+W

4P644480-1 – 2020.12

INFORMATION

Risk  of  space  heating  capacity  shortage  for  domestic  hot
water  tank  without  internal  booster  heater:  In  case  of
frequent  domestic  hot  water  operation,  frequent  and  long
space  heating/cooling  interruption  will  happen  when
selecting the following:

Tank

 > 

Heat up mode

 > 

Reheat only

.

INFORMATION

When  the  DHW  tank  mode  is  reheat,  the  risk  for  capacity
shortage  and  comfort  problem  is  significant.  In  case  of
frequent  reheat  operation,  space  heating/cooling  function
is regularly interrupted.

3.5.2

Scheduled mode

In scheduled mode the DHW tank produces hot water corresponding
to a schedule. The best time to allow the tank to produce hot water is
at night, because the space heating demand is lower.

Example: 

t

60°C

00:00

07:00

50°C

15°C

40°C

14:00

21:00

1

2

3

4

5

Tt

T

t

DHW tank temperature

t

Time

▪ Initially,  the  DHW  tank  temperature  is  the  same  as  the

temperature  of  the  domestic  water  entering  the  DHW  tank
(example: 

15°C

).

▪ At 00:00 the DHW tank is programmed to heat up the water to a

preset value (example: 

Comfort

 

= 60°C

).

▪ During  the  morning,  you  consume  hot  water  and  the  DHW  tank

temperature decreases.

▪ At 14:00 the DHW tank is programmed to heat up the water to a

preset value (example: 

Eco

 = 

50°C

). Hot water is available again.

▪ During  the  afternoon  and  evening,  you  consume  hot  water  again

and the DHW tank temperature decreases again.

▪ At 00:00 the next day, the cycle repeats.

3.5.3

Sch reheat mode

In  scheduled  +  reheat  mode,  the  domestic  hot  water  control  is  the
same  as  in  scheduled  mode.  However,  when  the  DHW  tank
temperature drops below a preset value (=reheat tank temperature –
hysteresis  value;  example:  35°C),  the  DHW  tank  heats  up  until  it
reaches  the  reheat  set  point  (example:  45°C).  This  ensures  that  a
minimum amount of hot water is available at all times.

Example: 

t

Tt

60°C

00:00

07:00

50°C

45°C

15°C

14:00

21:00

35°C

1

2

4

5

3

T

t

Domestic hot water tank temperature

t

Time

3.5.4

Using DHW powerful operation

About powerful operation

Powerful operation

 allows the domestic hot water to be heated by

the  backup  heater  or  booster  heater.  Use  this  mode  on  days  when
there is more hot water usage than usual.

To check if powerful operation is active

If 

 is displayed on the home screen, powerful operation is active.

Activate or deactivate 

Powerful operation

 as follows:

1

Go to [5.1]: 

Tank

 > 

Powerful operation

2

Turn powerful operation 

Off

 or 

On

.

Usage example: You immediately need more hot water

You are in the following situation:

▪ You already consumed most of your domestic hot water.

▪ You  cannot  wait  for  the  next  scheduled  action  to  heat  up  the

domestic hot water tank.

Then  you  can  activate  powerful  operation.  The  domestic  hot  water
tank will start heating up the water to the 

Comfort

 temperature.

INFORMATION

When  powerful  operation  is  active,  the  risk  of  space
heating/cooling and capacity shortage comfort problems is
significant.  In  case  of  frequent  domestic  hot  water
operation,  frequent  and  long  space  heating/cooling
interruptions will happen.

3.6

Advanced usage

The  amount  of  information  you  can  read  out  and  edit  in  the  menu
structure depends on your user permission level:

User

: Standard mode

Advanced user

: You can read out and edit more information

To change the user permission level

You can change the user permission level as follows:

1

Go to [B]: 

User profile

.

User profile

B

2

Enter the applicable pin code for the user permission
level.

▪ Browse  through  the  list  of  digits  and  change  the

selected digit.

▪ Move the cursor from left to right.

▪ Confirm the pin code and proceed.

User pin code

The 

User

 pin code is 

0000

.

0000

User

Summary of Contents for Altherma 3 H F+W EABH16DF6V

Page 1: ...sh Operation manual Daikin Altherma 3 H F W EABH16DF6V EABH16DF9W EABX16DF6V EABX16DF9W EAVH16S18DA6V G EAVH16SU18DA6V EAVH16S23DA6V G EAVH16SU23DA6V EAVH16S18DA9W G EAVH16S23DA9W G EAVX16S18DA6V G EA...

Page 2: ...equest the installer to inform you about the settings that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation f...

Page 3: ...function A malfunction occurred See 6 1 To display the help text in case of a malfunction 413 for more information LCD screen The LCD screen has a sleeping function After 15 min of non interaction wit...

Page 4: ...ank b1 b2 b1 Indoor unit Floor standing indoor unit with integrated tank Wall mounted indoor unit with separated tank Wall mounted indoor unit b2 Water pressure Space operation mode c Cooling Heating...

Page 5: ...liday mode and quiet mode 8 Information Displays data and information about the indoor unit 9 Installer settings Restriction Only for the installer Gives access to advanced settings A Commissioning Re...

Page 6: ...room thermostat control the protection is NOT guaranteed NOTICE Water pipe freeze prevention Even if you turn OFF space heating cooling operation C 2 Operation Space heating cooling water pipe freeze...

Page 7: ...temperature will stay the same as long as there is no scheduled action The desired room temperature will return to its scheduled value whenever a scheduled action occurs You can avoid scheduled behav...

Page 8: ...35 C the DHW tank heats up until it reaches the reheat set point example 45 C This ensures that a minimum amount of hot water is available at all times Example t Tt 60 C 00 00 07 00 50 C 45 C 15 C 14...

Page 9: ...2 Set scheduling to Yes 3 Go to 1 2 Room Heating schedule To clear the content of the week schedule 1 Select the name of the current schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 2 Select Delet...

Page 10: ...and edit the entry with the right dial 0 8 00 23 00 21 C 18 C 12 24 Sat 4 Confirm the changes 5 Select Saturday 6 Select Copy 7 Select Sunday 8 Select Paste Result Mon Sat Wed Fri Thu Tue Sun User def...

Page 11: ...7 User settings Language Time date Holiday Quiet Electricity price Gas price 8 Information Energy data Malfunction history Dealer information Sensors Actuators Operation modes About Connection status...

Page 12: ...heduled room temperature until the next scheduled action Example When you have a party or when you are leaving for a couple of hours For longer periods You can use the holiday mode Tips about DHW tank...

Page 13: ...e screen 6 2 Symptom You are feeling too cold hot in your living room Possible cause Corrective action The desired room temperature is too low high Increase decrease the desired room temperature See T...

Page 14: ...is displayed on the home screen of the user interface See 6 1 To display the help text in case of a malfunction 413 for more information about the malfunction a We recommend to purge air with the air...