background image

3 Operation

Operation manual

11

EABH/9W + EAVH/X16S(U)18+9W
Daikin Altherma 3 H F+W
4P644480-1 – 2020.12

3.8

Menu structure: Overview user settings

[1]

Room

Room sensor offset

Setpoint range

Antifrost

Cooling schedule

Heating schedule

Schedule

[2]

Main zone

Schedule
Heating schedule

Setpoint mode

Cooling schedule

Heating WD curve
Cooling WD curve

[3]

Additional zone

Schedule
Heating schedule

Setpoint mode

Cooling schedule

Heating WD curve
Cooling WD curve

[4]

Space heating/cooling

Operation mode
Operation mode schedule

[5]

Tank

Powerful operation
Comfort setpoint
Eco setpoint
Reheat setpoint
Schedule

[7]

User settings

Language
Time/date
Holiday
Quiet
Electricity price
Gas price

[8]

Information

Energy data

Malfunction history

Dealer information

Sensors
Actuators
Operation modes
About
Connection status

[B]

User profile

[C]

Operation

Room

Space heating/cooling

Tank

[1.4]

Antifrost

Activation
Room setpoint

[1.5]

Setpoint range

Heating minimum
Heating maximum
Cooling minimum
Cooling maximum

[7.2]

Time/date

Hours
Minutes
Year
Month
Day
Daylight savings time
Format

[7.3]

Holiday

Activation
From
Till

[7.4]

Quiet

Activation
Schedule

[7.5]

Electricity price

High
Medium
Low
Schedule

[8.1]

Energy data

Electricity input
Produced heat

(*)

(*)

(*)

(*)

(*)

(*)

(*)

(*)

Setpoint screen

(*)

Only applicable for reversible models, or heating only conversion kit

INFORMATION

Depending on the selected installer settings and unit type,
settings will be visible/invisible.

Summary of Contents for Altherma 3 H F+W EABH16DF6V

Page 1: ...sh Operation manual Daikin Altherma 3 H F W EABH16DF6V EABH16DF9W EABX16DF6V EABX16DF9W EAVH16S18DA6V G EAVH16SU18DA6V EAVH16S23DA6V G EAVH16SU23DA6V EAVH16S18DA9W G EAVH16S23DA9W G EAVX16S18DA6V G EA...

Page 2: ...equest the installer to inform you about the settings that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation f...

Page 3: ...function A malfunction occurred See 6 1 To display the help text in case of a malfunction 413 for more information LCD screen The LCD screen has a sleeping function After 15 min of non interaction wit...

Page 4: ...ank b1 b2 b1 Indoor unit Floor standing indoor unit with integrated tank Wall mounted indoor unit with separated tank Wall mounted indoor unit b2 Water pressure Space operation mode c Cooling Heating...

Page 5: ...liday mode and quiet mode 8 Information Displays data and information about the indoor unit 9 Installer settings Restriction Only for the installer Gives access to advanced settings A Commissioning Re...

Page 6: ...room thermostat control the protection is NOT guaranteed NOTICE Water pipe freeze prevention Even if you turn OFF space heating cooling operation C 2 Operation Space heating cooling water pipe freeze...

Page 7: ...temperature will stay the same as long as there is no scheduled action The desired room temperature will return to its scheduled value whenever a scheduled action occurs You can avoid scheduled behav...

Page 8: ...35 C the DHW tank heats up until it reaches the reheat set point example 45 C This ensures that a minimum amount of hot water is available at all times Example t Tt 60 C 00 00 07 00 50 C 45 C 15 C 14...

Page 9: ...2 Set scheduling to Yes 3 Go to 1 2 Room Heating schedule To clear the content of the week schedule 1 Select the name of the current schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 2 Select Delet...

Page 10: ...and edit the entry with the right dial 0 8 00 23 00 21 C 18 C 12 24 Sat 4 Confirm the changes 5 Select Saturday 6 Select Copy 7 Select Sunday 8 Select Paste Result Mon Sat Wed Fri Thu Tue Sun User def...

Page 11: ...7 User settings Language Time date Holiday Quiet Electricity price Gas price 8 Information Energy data Malfunction history Dealer information Sensors Actuators Operation modes About Connection status...

Page 12: ...heduled room temperature until the next scheduled action Example When you have a party or when you are leaving for a couple of hours For longer periods You can use the holiday mode Tips about DHW tank...

Page 13: ...e screen 6 2 Symptom You are feeling too cold hot in your living room Possible cause Corrective action The desired room temperature is too low high Increase decrease the desired room temperature See T...

Page 14: ...is displayed on the home screen of the user interface See 6 1 To display the help text in case of a malfunction 413 for more information about the malfunction a We recommend to purge air with the air...

Page 15: ......

Page 16: ...4P644480 1 2020 12 Copyright 2018 Daikin 4P644480 1 0000000O Verantwortung f r Energie und Umwelt...

Reviews: