background image

3 Operation

Operation manual

5

EABH/9W + EAVH/X16S(U)18+9W
Daikin Altherma 3 H F+W
4P644480-1 – 2020.12

a

2

Main zone

Additional zone

Room

Malfunctioning

Space heating/cooling

a

Selected submenu

Possible actions on this screen

Go through the list.

Enter the submenu.

Enable/disable breadcrumbs.

Submenu

Description

[0]

 or 

Malfunctioning

Restriction: 

Only displayed if a

malfunction occurs.

See 

"6.1 To display the help text in

case of a malfunction"

 [

4

 13] for more

information.

[1]

 

Room

Restriction: 

Only displayed if a room

thermostat is connected to the indoor
unit.

Set the room temperature.

[2]

 

Main zone

Shows the applicable symbol for your
main zone emitter type.

Set the leaving water temperature for
the main zone.

[3]

 

Additional zone

Restriction: 

Only displayed if there

are two leaving water temperature
zones. Shows the applicable symbol
for your additional zone emitter type.

Set the leaving water temperature for
the additional zone (if present).

[4]

 

Space heating/

cooling

Shows the applicable symbol for your
unit.

Put the unit in heating mode or cooling
mode. You cannot change the mode
on heating only models.

[5]

 

Tank

Restriction: 

Only displayed if a

domestic hot water tank is present.

Set the domestic hot water tank
temperature.

[7]

 

User settings

Gives access to user settings such as
holiday mode and quiet mode.

[8]

 

Information

Displays data and information about
the indoor unit.

[9]

 

Installer

settings

Restriction: 

Only for the installer.

Gives access to advanced settings.

[A]

 

Commissioning

Restriction: 

Only for the installer.

Perform tests and maintenance.

[B]

 

User profile

Change the active user profile.

[C]

 

Operation

Turn heating/cooling functionality and
domestic hot water preparation on or
off.

3.2.3

Setpoint screen

The  setpoint  screen  is  displayed  for  screens  describing  system
components that need a setpoint value.

Examples

[1] Room temperature screen

+

21

°C

1

Room

[2] Main zone screen

+

35

°C

2

Main zone

[3] Additional zone screen

+

45

°C

3

Additional zone

[5] Tank temperature screen

+

50

°C

5

Tank

Explanation

a1

d

+

d

e

d

e

c

a2

b1

b2

Possible actions on this screen

Go through the list of the submenu.

Go to the submenu.

Adjust and automatically apply the desired
temperature.

Item

Description

Minimum temperature limit

a1

Fixed by the unit

a2

Restricted by the installer

Maximum temperature limit

b1

Fixed by the unit

b2

Restricted by the installer

Current temperature

c

Measured by the unit

Desired temperature

d

Turn the right dial to
increase/decrease.

Submenu

e

Turn or press the left dial to
go to the submenu.

3.2.4

Detailed screen with values

Example: 

a

b

c

a

b

c

7.2.1

Time/date

Hours

11

30

Minutes

a Settings

b Values

c Selected setting and value

Possible actions on this screen

Go through the list of settings.

Change the value.

Go to the next setting.

Confirm changes and proceed.

Summary of Contents for Altherma 3 H F+W EABH16DF6V

Page 1: ...sh Operation manual Daikin Altherma 3 H F W EABH16DF6V EABH16DF9W EABX16DF6V EABX16DF9W EAVH16S18DA6V G EAVH16SU18DA6V EAVH16S23DA6V G EAVH16SU23DA6V EAVH16S18DA9W G EAVH16S23DA9W G EAVX16S18DA6V G EA...

Page 2: ...equest the installer to inform you about the settings that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation f...

Page 3: ...function A malfunction occurred See 6 1 To display the help text in case of a malfunction 413 for more information LCD screen The LCD screen has a sleeping function After 15 min of non interaction wit...

Page 4: ...ank b1 b2 b1 Indoor unit Floor standing indoor unit with integrated tank Wall mounted indoor unit with separated tank Wall mounted indoor unit b2 Water pressure Space operation mode c Cooling Heating...

Page 5: ...liday mode and quiet mode 8 Information Displays data and information about the indoor unit 9 Installer settings Restriction Only for the installer Gives access to advanced settings A Commissioning Re...

Page 6: ...room thermostat control the protection is NOT guaranteed NOTICE Water pipe freeze prevention Even if you turn OFF space heating cooling operation C 2 Operation Space heating cooling water pipe freeze...

Page 7: ...temperature will stay the same as long as there is no scheduled action The desired room temperature will return to its scheduled value whenever a scheduled action occurs You can avoid scheduled behav...

Page 8: ...35 C the DHW tank heats up until it reaches the reheat set point example 45 C This ensures that a minimum amount of hot water is available at all times Example t Tt 60 C 00 00 07 00 50 C 45 C 15 C 14...

Page 9: ...2 Set scheduling to Yes 3 Go to 1 2 Room Heating schedule To clear the content of the week schedule 1 Select the name of the current schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 2 Select Delet...

Page 10: ...and edit the entry with the right dial 0 8 00 23 00 21 C 18 C 12 24 Sat 4 Confirm the changes 5 Select Saturday 6 Select Copy 7 Select Sunday 8 Select Paste Result Mon Sat Wed Fri Thu Tue Sun User def...

Page 11: ...7 User settings Language Time date Holiday Quiet Electricity price Gas price 8 Information Energy data Malfunction history Dealer information Sensors Actuators Operation modes About Connection status...

Page 12: ...heduled room temperature until the next scheduled action Example When you have a party or when you are leaving for a couple of hours For longer periods You can use the holiday mode Tips about DHW tank...

Page 13: ...e screen 6 2 Symptom You are feeling too cold hot in your living room Possible cause Corrective action The desired room temperature is too low high Increase decrease the desired room temperature See T...

Page 14: ...is displayed on the home screen of the user interface See 6 1 To display the help text in case of a malfunction 413 for more information about the malfunction a We recommend to purge air with the air...

Page 15: ......

Page 16: ...4P644480 1 2020 12 Copyright 2018 Daikin 4P644480 1 0000000O Verantwortung f r Energie und Umwelt...

Reviews: