background image

3 Operation

Operation manual

4

EABH/9W + EAVH/X16S(U)18+9W

Daikin Altherma 3 H F+W

4P644480-1 – 2020.12

+

a

OR

b

c

c2

c4

c1

c3

a

Home screen

b

Main menu screen

c

Lower level screens:

c1

: Setpoint screen

c2

: Detailed screen with values

c3

: Screen with weather-dependent curve

c4

: Screen with schedule

3.2.1

Home screen

Press  the 

  button  to  go  back  to  the  home  screen.  You  see  an

overview  of  the  unit  configuration  and  the  room  and  setpoint
temperatures.  Only  symbols  applicable  for  your  configuration  are
visible on the home screen.

6

1.6

bar

18 Feb 2018

22:19

55

45

21
35

f

i

j

h

g

e

d

a

b

c

Possible actions on this screen

Go through the list of the main menu.

Go to the main menu screen.

Enable/disable breadcrumbs.

Item

Description

21

21

The temperatures are shown in circles. If the circle
is grey, the corresponding operation (example:
space heating) is currently not active.

Outdoor
unit

a2 a3

a1

a1

: Outdoor unit

a2

: Quiet mode active

a3

Measured ambient temperature

Item

Description

Indoor unit /
domestic
hot water
tank

b1

b2

b1

Indoor unit:

: Floor-standing indoor unit with integrated

tank

: Wall-mounted indoor unit with separated

tank

: Wall-mounted indoor unit

b2

Water pressure

Space
operation
mode

c

: Cooling

: Heating

Disinfection
 / Powerful

d

: Disinfection mode active

: Powerful operation active

Date / time

e

Current date and time

Holiday

f

: Holiday mode active

Main zone

g3
g1

g4
g2

g1

Heat emitter type:

Underfloor heating

Fancoil unit

Radiator

g2

Leaving water temperature setpoint

g3

Room thermostat type:

:  Daikin  user  interface  used  as  room

thermostat

: External control

▪ Hidden: Leaving water temperature control

g4

Measured room temperature

Additional
zone

h3
h1 h2

h1

Heat emitter type:

Underfloor heating

Fancoil unit

Radiator

h2

Leaving water temperature setpoint

h3

Room thermostat type:

: External control

▪ Hidden: Leaving water temperature control

Domestic
hot water

i1 i2

i1

: Domestic hot water

i2

Measured tank temperature

Malfunction

j

 or 

: A malfunction occurred

See 

"6.1 To display the help text in case of a

malfunction"

 [

4

 13] for more information.

3.2.2

Main menu screen

Starting from the home screen, press (

) or turn (

) the

left  dial  to  open  the  main  menu  screen.  From  the  main  menu,  you
can access the different setpoint screens and submenus.

Summary of Contents for Altherma 3 H F+W EABH16DF6V

Page 1: ...sh Operation manual Daikin Altherma 3 H F W EABH16DF6V EABH16DF9W EABX16DF6V EABX16DF9W EAVH16S18DA6V G EAVH16SU18DA6V EAVH16S23DA6V G EAVH16SU23DA6V EAVH16S18DA9W G EAVH16S23DA9W G EAVX16S18DA6V G EA...

Page 2: ...equest the installer to inform you about the settings that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation f...

Page 3: ...function A malfunction occurred See 6 1 To display the help text in case of a malfunction 413 for more information LCD screen The LCD screen has a sleeping function After 15 min of non interaction wit...

Page 4: ...ank b1 b2 b1 Indoor unit Floor standing indoor unit with integrated tank Wall mounted indoor unit with separated tank Wall mounted indoor unit b2 Water pressure Space operation mode c Cooling Heating...

Page 5: ...liday mode and quiet mode 8 Information Displays data and information about the indoor unit 9 Installer settings Restriction Only for the installer Gives access to advanced settings A Commissioning Re...

Page 6: ...room thermostat control the protection is NOT guaranteed NOTICE Water pipe freeze prevention Even if you turn OFF space heating cooling operation C 2 Operation Space heating cooling water pipe freeze...

Page 7: ...temperature will stay the same as long as there is no scheduled action The desired room temperature will return to its scheduled value whenever a scheduled action occurs You can avoid scheduled behav...

Page 8: ...35 C the DHW tank heats up until it reaches the reheat set point example 45 C This ensures that a minimum amount of hot water is available at all times Example t Tt 60 C 00 00 07 00 50 C 45 C 15 C 14...

Page 9: ...2 Set scheduling to Yes 3 Go to 1 2 Room Heating schedule To clear the content of the week schedule 1 Select the name of the current schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 2 Select Delet...

Page 10: ...and edit the entry with the right dial 0 8 00 23 00 21 C 18 C 12 24 Sat 4 Confirm the changes 5 Select Saturday 6 Select Copy 7 Select Sunday 8 Select Paste Result Mon Sat Wed Fri Thu Tue Sun User def...

Page 11: ...7 User settings Language Time date Holiday Quiet Electricity price Gas price 8 Information Energy data Malfunction history Dealer information Sensors Actuators Operation modes About Connection status...

Page 12: ...heduled room temperature until the next scheduled action Example When you have a party or when you are leaving for a couple of hours For longer periods You can use the holiday mode Tips about DHW tank...

Page 13: ...e screen 6 2 Symptom You are feeling too cold hot in your living room Possible cause Corrective action The desired room temperature is too low high Increase decrease the desired room temperature See T...

Page 14: ...is displayed on the home screen of the user interface See 6 1 To display the help text in case of a malfunction 413 for more information about the malfunction a We recommend to purge air with the air...

Page 15: ......

Page 16: ...4P644480 1 2020 12 Copyright 2018 Daikin 4P644480 1 0000000O Verantwortung f r Energie und Umwelt...