3 Operation

Operation manual

9

EABH/9W + EAVH/X16S(U)18+9W
Daikin Altherma 3 H F+W
4P644480-1 – 2020.12

Advanced user pin code

The 

Advanced user

 pin code is 

1234

. Additional menu items for the

user are now visible.

1234

Advanced user

3.7

Schedule screen: Example

This  example  shows  how  to  set  a  room  temperature  schedule  in
heating mode for the main zone.

INFORMATION

The procedures to program other schedules are similar.

To program the schedule: overview

Example: 

You want to program the following schedule:

Mon

Sat

Wed

Fri

Thu

Tue

Sun

User defined 1

Prerequisite: 

The  room  temperature  schedule  is  only  available  if

room  thermostat  control  is  active.  If  leaving  water  temperature
control is active, you can program the main zone schedule instead.

1

Go to the schedule.

2

(optional) Clear the content of the whole week schedule or the
content of a selected day schedule.

3

Program the schedule for 

Monday

.

4

Copy the schedule to the other weekdays.

5

Program the schedule for 

Saturday

 and copy it to 

Sunday

.

6

Give the schedule a name.

To go to the schedule

1

Go to [1.1]: 

Room

 > 

Schedule

.

2

Set scheduling to 

Yes

.

3

Go to [1.2]: 

Room

 > 

Heating schedule

.

To clear the content of the week schedule

1

Select the name of the current schedule.

Mon

Sat

Wed

Fri

Thu

Tue

Sun

User defined 1

2

Select 

Delete

.

Delete

Rename

Select

3

Select 

OK

 to confirm.

To clear the content of a day schedule

1

Select the day of which you want to clear the
content. For example 

Friday

Mon

Sat

Wed

Fri

Thu

Tue

Sun

User defined 1

C

2

Select 

Delete

.

Delete

Edit

Copy

3

Select 

OK

 to confirm.

To program the schedule for Monday

1

Select 

Monday

.

Mon

Sat

Wed

Fri

Thu

Tue

Sun

User defined 1

2

Select 

Edit

.

Delete

Edit

Copy

3

Use the left dial to select an entry and edit the entry
with the right dial. You can program up to 6 actions
each day. On the bar, a high temperature has a
darker colour than a low temperature.

0

6:00
8:30

17:30

20°C
18°C

22:00

--:--

18°C

--

21°C

12

24

Mon

Note: 

To clear an action, set its time as the time of

the previous action.

4

Confirm the changes.

Result: 

The schedule for Monday is defined. The

value of the last action is valid until the next
programmed action. In this example, Monday is the
first day you programmed. Thus, the last
programmed action is valid up to the first action of
next Monday.

To copy the schedule to the other weekdays

1

Select 

Monday

.

Mon

Sat

Wed

Fri

Thu

Tue

Sun

User defined 1

Summary of Contents for Altherma 3 H F+W EABH16DF6V

Page 1: ...sh Operation manual Daikin Altherma 3 H F W EABH16DF6V EABH16DF9W EABX16DF6V EABX16DF9W EAVH16S18DA6V G EAVH16SU18DA6V EAVH16S23DA6V G EAVH16SU23DA6V EAVH16S18DA9W G EAVH16S23DA9W G EAVX16S18DA6V G EA...

Page 2: ...equest the installer to inform you about the settings that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation f...

Page 3: ...function A malfunction occurred See 6 1 To display the help text in case of a malfunction 413 for more information LCD screen The LCD screen has a sleeping function After 15 min of non interaction wit...

Page 4: ...ank b1 b2 b1 Indoor unit Floor standing indoor unit with integrated tank Wall mounted indoor unit with separated tank Wall mounted indoor unit b2 Water pressure Space operation mode c Cooling Heating...

Page 5: ...liday mode and quiet mode 8 Information Displays data and information about the indoor unit 9 Installer settings Restriction Only for the installer Gives access to advanced settings A Commissioning Re...

Page 6: ...room thermostat control the protection is NOT guaranteed NOTICE Water pipe freeze prevention Even if you turn OFF space heating cooling operation C 2 Operation Space heating cooling water pipe freeze...

Page 7: ...temperature will stay the same as long as there is no scheduled action The desired room temperature will return to its scheduled value whenever a scheduled action occurs You can avoid scheduled behav...

Page 8: ...35 C the DHW tank heats up until it reaches the reheat set point example 45 C This ensures that a minimum amount of hot water is available at all times Example t Tt 60 C 00 00 07 00 50 C 45 C 15 C 14...

Page 9: ...2 Set scheduling to Yes 3 Go to 1 2 Room Heating schedule To clear the content of the week schedule 1 Select the name of the current schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 2 Select Delet...

Page 10: ...and edit the entry with the right dial 0 8 00 23 00 21 C 18 C 12 24 Sat 4 Confirm the changes 5 Select Saturday 6 Select Copy 7 Select Sunday 8 Select Paste Result Mon Sat Wed Fri Thu Tue Sun User def...

Page 11: ...7 User settings Language Time date Holiday Quiet Electricity price Gas price 8 Information Energy data Malfunction history Dealer information Sensors Actuators Operation modes About Connection status...

Page 12: ...heduled room temperature until the next scheduled action Example When you have a party or when you are leaving for a couple of hours For longer periods You can use the holiday mode Tips about DHW tank...

Page 13: ...e screen 6 2 Symptom You are feeling too cold hot in your living room Possible cause Corrective action The desired room temperature is too low high Increase decrease the desired room temperature See T...

Page 14: ...is displayed on the home screen of the user interface See 6 1 To display the help text in case of a malfunction 413 for more information about the malfunction a We recommend to purge air with the air...

Page 15: ......

Page 16: ...4P644480 1 2020 12 Copyright 2018 Daikin 4P644480 1 0000000O Verantwortung f r Energie und Umwelt...

Reviews: