SiBE121135
Outdoor Unit: 40-75 Class
Removal Procedure
365
1.9
Removal of Compressor
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1
Remove the terminal
cover.
2
Disconnect the
compressor lead wires.
3
Detach the overload
protector.
(R12914)
Terminal cover
V(yellow)
U(red)
W(blue)
(R5602)
(R12916)
Overload protector
(R5604)