Cooling Only
SiBE121135
16
Specifications
50 Hz, 230 V
Note:
The data are based on the conditions shown in the table below.
Model
4MKS75F2V1B
5MKS90E2V3B
Casing Color
Ivory White
Ivory White
Compressor
Type
Hermetically Sealed Swing Type
Hermetically Sealed Swing Type
Model
2YC45DXD
2YC63BXD
Motor Output
W
1,380
1,920
Refrigerant Oil
Model
FVC50K
FVC50K
Charge
L
0.65
0.75
Refrigerant
Type
R-410A
R-410A
Charge
kg
2.3
2.95
Airflow Rate
H
m³/min
52.7
54.5
M
49.4
—
L
43.5
46
H
cfm
1,861
1,924
M
1,744
—
L
1,536
1,624
Fan
Type
Propeller
Propeller
Motor Output
W
53
66
Running Current
A
H: 0.20 / M: 0.16 / L: 0.10
H: 0.97 / L: 0.69
Power Consumption
W
H: 70 / M: 58 / L: 36
H: 86 / L: 55
Starting Current
A
6.2
11.4
Dimensions (H × W × D)
mm
735 × 936 × 300
770 × 900 × 320
Packaged Dimensions (H × W × D)
mm
797 × 992 × 390
900 × 925 × 390
Weight (Mass)
kg
57
69
Gross Weight (Gross Mass)
kg
61
78
Sound Pressure Level
dB(A)
48
48
Sound Power Level
dB
61
62
Piping
Connection
Liquid
mm
φ
6.4 × 4
φ
6.4 × 5
Gas
mm
φ
9.5 × 2,
φ
12.7 × 1,
φ
15.9 × 1
φ
9.5 × 2,
φ
12.7 × 1,
φ
15.9 × 2
Drain
mm
φ
18.0
φ
25.0
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
No. of Wiring Connection
3 for Power Supply, 4 for Interunit Wiring
3 for Power Supply, 4 for Interunit Wiring
Max. Interunit Piping Length
m
60 (for Total of Each Room)
75 (for Total of Each Room)
m
25 (for One Room)
25 (for One Room)
Amount of Additional Charge
g/m
Chargeless
20 (65 m or more)
Max. Installation Height Difference
m
15 (between Indoor Unit and Outdoor Unit)
15 (between Indoor Unit and Outdoor Unit)
m
15 (between Indoor Units)
7.5 (between Indoor Units)
Drawing No.
3D056453
3D063120
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
Cooling
Piping Length
Indoor ; 27°CDB / 19°CWB
Outdoor ; 35°CDB
5 m (4MKS75F2V1B)
7.5 m (5MKS90E2V3B)