Indoor Unit Control (RA Models)
SiBE121135
98
Function and Control
1.17.7 Auto-restart Function
If a power failure (including one for just a moment) occurs during the operation, the operation
restarts automatically when the power is restored in the same condition as before the power
failure.
Note:
It takes 3 minutes to restart the operation because the 3-minute standby function is activated.
1.17.8 WEEKLY TIMER Operation
Up to 4 timer settings can be saved for each day of the week (up to 28 settings in total).
Those 3 items of “ON/OFF”, “temperature” and “time” can be set.
Refer to “WEEKLY TIMER Operation” on page 167, 208 for detail.
1.17.9 Brightness Setting of the Indoor Unit Display
Floor Standing Type: FVXG Series
Each time you press the [Brightness] button on the remote controller, the brightness of the
indoor unit display changes to “high”, “low”, or “off”.
Refer to the operation manual for details.
Timer lamp (yellow)
Radiant lamp (red)
Indoor unit display
(R14639)
Operation lamp
(green)