SQLC-220-086
48
◆ 213 Current display intrinsic sensitivity
Set the full scale of current meter.
The setting range is from 40 to 120% of the current range
and can be selected from the [Current display intrinsic
sensitivity (full scale) list].
Selection by + and - , set value is updated by SET .
Default setting:100.0A
<Example>
When the current range is 100A.
From 40% of current range = 40A and 120% of current range = 120A,
display intrinsic sensitivity can be selected from [Current
display intrinsic sensitivity (full scale) list] in the range
of 40A to 120A.
Setting range:40.0A/42.0A/45.0A/48.0A/50.0A/56.0A/60.0A/
64.0A/72.0A/75.0A/80.0A/84.0A/90.0A/96.0A/
100.0A/100A/120.0A/120A
<Note> Changing this setting does not change the analog output sensitivity.
When changing the sensitivity of analog output, set "225A current output intrinsic sensitivity
【 Current display intrinsic sensitivity (full scale) list 】
Full scale
Full scale
Full scale
Full scale
3 digits
4 digits
3 digits
4 digits
3 digits
4 digits
3 digits
4 digits
40.0A
400A
4.00kA
4000A
42.0A
420A
4.20kA
4200A
45.0A
450A
4.50kA
4500A
48.0A
480A
4.80kA
4800A
5.00A
50.0A
500A
5.00kA
5000A
5.60A
56.0A
560A
5.60kA
5600A
6.00A
60.0A
600A
6.00kA
6000A
6.40A
64.0A
640A
6.40kA
6400A
7.20A
72.0A
720A
7.20kA
7200A
7.50A
75.0A
750A
7.50kA
7500A
8.00A
80.0A
800A
8.00kA
8000A
8.40A
84.0A
840A
8.40kA
9.00A
90.0A
900A
9.00kA
9.60A
96.0A
960A
9.60kA
10.0A
10.00A
100A
100.0A
1.00kA
1000A
10.0kA
10.00kA
12.0A
12.00A
120A
120.0A
1.20kA
1200A
12.0kA
12.00kA
14.0A
14.00A
140A
140.0A
1.40kA
1400A
14.0kA
14.00kA
15.0A
15.00A
150A
150.0A
1.50kA
1500A
15.0kA
15.00kA
16.0A
16.00A
160A
160.0A
1.60kA
1600A
16.0kA
16.00kA
18.0A
18.00A
180A
180.0A
1.80kA
1800A
18.0kA
18.00kA
20.0A
20.00A
200A
200.0A
2.00kA
2000A
20.0kA
20.00kA
24.0A
24.00A
240A
240.0A
2.40kA
2400A
24.0kA
24.00kA
25.0A
25.00A
250A
250.0A
2.50kA
2500A
25.0kA
25.00kA
28.0A
28.00A
280A
280.0A
2.80kA
2800A
28.0kA
28.00kA
30.0A
30.00A
300A
300.0A
3.00kA
3000A
30.0kA
30.00kA
32.0A
32.00A
320A
320.0A
3.20kA
3200A
32.0kA
32.00kA
36.0A
36.00A
360A
360.0A
3.60kA
3600A
36.0kA
36.00kA
Current display intrinsic
sensitivity
Setting factor
Setting No.
New setting
Current setting
Full scale
Changing the display specific
sensitivity changes the full scale
of the bar graph.