Chapter 6
W
elding Condition
6.7.2.46 F61: Pulse peak time fine adjustment
This function allows fine adjustment of the standard pulse peak time; by setting the adjustment value, finely adjusted
pulse peak time can be obtained.
Moreover, in the pulse condition of the wave pulse welding at HIGH side, fine adjustment is available to the standard
pulse peak time at HIGH side by setting the adjustment value.
Example of current waveform of wave pulse welding (
-
F65: L-base current fine adjustment)
Set the adjustment value in the range of -1.5 to 1.5 ms.
Fine adjustment of unit pulse condition (
-
F60: Pulse peak current fine adjustment, <Fine adjustment of unit
pulse condition>)
Example of current waveform of wave pulse welding (
-
F65: L-base current fine adjustment)
6.7.2.47 F62: Base current fine adjustment
This function allows fine adjustment of the standard base current; by setting the adjustment value, finely adjusted base
current can be obtained.
Set the adjustment value in the range of -60 to 60 A.
Fine adjustment of unit pulse condition (
-
F60: Pulse peak current fine adjustment, <Fine adjustment of unit
pulse condition>)
6.7.2.48 F63: L pulse peak current fine adjustment
This function allows fine adjustment of the standard pulse peak current at LOW side in the pulse condition of the wave
pulse welding; by setting the adjustment value, finely adjusted pulse peak current at LOW side can be obtained.
Set the adjustment value in the range of -150 to 150 A.
Fine adjustment of unit pulse condition (
-
F60: Pulse peak current fine adjustment, <Fine adjustment of unit
pulse condition>)
Example of current waveform of wave pulse welding (
-
F65: L-base current fine adjustment)
6.7.2.49 F64: L pulse peak time fine adjustment
This function allows fine adjustment of the standard pulse peak time at LOW side in the pulse condition of the wave pulse
welding; by setting the adjustment value, finely adjusted pulse peak time at LOW side can be obtained.
Set the adjustment value in the range of -1.5 to 1.5 ms.
Fine adjustment of unit pulse condition (
-
F60: Pulse peak current fine adjustment, <Fine adjustment of unit
pulse condition>)
Example of current waveform of wave pulse welding (
-
F65: L-base current fine adjustment)
6.7.2.50 F65: L-base current fine adjustment
This function allows fine adjustment of the standard pulse base current at LOW side in the pulse condition of the wave
pulse welding; by setting the adjustment value, finely adjusted pulse base current at LOW side can be obtained.
Set the adjustment value in the range of -60 to 60 A.
Fine adjustment of unit pulse condition (
-
F60: Pulse peak current fine adjustment, <Fine adjustment of unit
pulse condition>)
<Example of current waveform of wave pulse welding>
Pulse condition at HIGH side
Pulse condition at LOW side
Pulse condition at HIGH side
Current value
Time
Pulse peak current at LOW side
Pulse peak current at HIGH side
Base current at HIGH side
Base current at LOW side