C
ONNECTION
OF
E
XTERNAL
E
QUIPMENT
C
ONNECTION
C
HAPTER
4
42
4.5.1.2
Wiring of wire feeder
In the welding of DC low spatter, wiring of the wire feeder needs to be changed and voltage detection from the torch end
is required.
1.
Check that input power is turned off with the switch in the switch box connected to the welding power source.
2.
Remove (or open) plates in the right side and left side of the wire feeder.
3.
Remove the voltage detection cable (line No. 309) connected to the terminal block and connect the voltage
detection cable for torch side (K5416P00: optional accessory)
●
Connect the other end of the voltage detection cable for torch side (K5416P00) to the tip of the torch.
No.
Product name/Model
Remarks
1
Welding power source
2
Interface: IFR-101WB
Connection robot controller cable
(optional) is also available. (
Refer to
instruction manual of Interface)
3
Wire feeder
Wiring for wire feeder needs to be
changed.
(
4
Welding torch: K2331 type curved torch
5
Uni-cord power cable:
K5369(1.1 m), K5370(1.2 m)
6
Control cable for wire feeder: BKCPJ-1010 (10 m)
For details on cables, see: (
Details on extension cables and hoses)
7
Power cable (torch side):
BKPDT-6012 (*1)
BKPDT-8012 (*2)
8
Power cable (base metal side):
BKPDT-6012 (*1)
BKPDT-8012 (*2)
9
Gas hose: BKGG-0610 (10 m)
10
Gas regulator
To be prepared by the customer.
11
Conduit: Z318P50
(Guide adaptor attachment part: 9/16-18UNF)
When using the conduit 7/16-20UNF,
guide adaptor L7810D04 is also
required.
12
Voltage detection cable (torch side): K5416P00 (3m)
Wiring for wire feeder needs to be
changed.
(
*1: WB-P402L
*2: WB-P502L
•
Perform the work after turning the input power off with the switch in the switch box
connected to the welding power source. Otherwise, electric shock may occur.
㻟㻜㻤
㻟㻜㻤
㻟㻜㻥
㻟㻜㻥
㻟㻝㻜
㻟㻜㻠
㻟㻜㻡
㻟㻜㻢
㻟㻜㻝
㻟㻜㻞
㻟㻜㻟
㻟㻜㻠
㻟㻜㻡
㻟㻜㻢
㻟㻜㻣
㻟㻜㻟
㻟㻜㻞
㻟㻜㻝
Terminal block
Control cable
Voltage detection cable
(Line No. 309)
Wire feeder
Bracket
Voltage detection cable