F
UNCTION
ON
O
PERATION
P
ANEL
W
ELDING
C
ONDITION
C
HAPTER
6
66
•
MENU screen
WIRE MATERIALS
Select the wire material to use.
•
Some wire material cannot be used depending on the combination of the wire diameter, gas, welding
process, and Manual/Auto. The wire material that cannot be used will not be displayed.
(
•
If other welding JOB are changed, and if combination of the changed welding JOB makes the currently set
wire diameter to become invalid, the color of the wire diameter parameter will become inverted on the LCD
panel display, and "- - -" will flash on the left/right digital meters.
GAS
Select the gas to use.
•
Some gas cannot be used depending on the combination of the wire material, wire diameter, welding
process, and Manual/Auto. The gas that cannot be used will not be displayed.
(
•
If other welding JOB are changed, and if combination of the changed welding JOB makes the currently set
welding process invalid, the color of the WELDING PROCESS parameter will become inverted on the LCD
panel display, and "- - -" will flash on the left/right digital meters.
WIRE DIA. (mm)
Select the wire diameter to use.
•
Some wire diameter cannot be used depending on the combination of the wire material, gas, welding
process, and Manual/Auto. The wire diameter that cannot be used will not be displayed.
(
•
If other welding JOB are changed, and if combination of the changed welding JOB makes the currently set
wire diameter to become invalid, the color of the wire diameter parameter will become inverted on the LCD
panel display, and "- - -" will flash on the left/right digital meters.
Manual/Auto.
Select the Manual/Auto. to apply.
•
Some option is invalid depending on the combination of the wire diameter, wire material, gas, and welding
process. The invalid option will not be displayed. (
2T/4T
Select 2T/4T trigger with the crater treatment method or arc spot at the end of welding.
•
For details of 2T/4T (
•
For details of arc spot (
SPOT TIME
Sets the Arc spot time.
This item is displayed when "ARC SPOT" is selected by the 2T/4T menu. (
Start Condition
When "4T" is selected by the 2T/4T menu, the sequence of start condition is added before the welding. (
-
Crater setting)
Pressing the screen operation knob makes the turning ON/OFF.
Synergic ON/OFF
Sets welding voltage. Switching the mode is enabled.
Switching the mode is enabled by pressing the screen operation knob.
•
"Synergic: ON": Synergic mode. (The welding voltage is automatically set according to the set welding current.
To fine-tune welding voltage, adjust the synergic fine adjustment knob.)
•
"Synergic: OFF": INDIVIDUAL mode. (In the individual adjustment setting, welding current and welding voltage
are adjusted respectively.)
Welding guide
By setting the "WELD JOINT" and "PLATE THICKNESS", the welding current will be set automatically according to
each parameter. (
-
Item
Functions
Function
Sets the internal function of welding power source. (
6.7 Setting Internal Functions)
LOAD JOB
Reads the registered welding condition from the internal memory. (
-
Memory Function of Welding JOB)
SAVE JOB
Registers the set welding condition in the internal memory. (
6.5 Memory Function of Welding JOB)
WELD MONITOR
Sets welding control function. (
Chapter 7 Administrator Functions))
KEY LOCK
Switches between KEY LOCK ON/OFF. (
7.1.2 Disabling erroneous operation prevention)
BACKUP
Backs up the data such as welding JOB in USB flash drive. (
RESTORE
Imports the backed-up data to this welding power source. (
PRODUCT INFO
Displays the information on the software and serial number of this welding power source. (
Software Version and Serial Number)
SYSTEM SETTING
Sets the "LCD Background" and the "language" of all screens.
Item