79
-
14. SPECIFICATIONS
(Continued)
14.3 Initial Value and Setting Range
●
Initial Value and Setting Range of Parameters
Initial value
Setting range
CPTX-I 400 2W
CPTX-I 500 2W
·Initial condition
·Main welding condition
·Crater-fill condition
Current
100 A
30–450A
30-550A
Voltage
19 V
12–45V
12-50V
Fine adjustment of voltage
0
-30–30
ARC
Spot Time
3 sec.
0.1–10 sec.
ARC CHARACTERISTICS
0
-99–99
Memory Number for Welding Condition
1
1–30
●
Function
Initial Value
Setting Item
CPTX-I 400 2W
CPTX-I 500 2W
Crater Filler
OFF
OFF / ON / REPEAT / ARC SPOT
Shielding gas
CO
2
CO
2
/MAG/MIG/DC STICK
Wire Type
MILD STEEL SOLID
MILD STEEL SOLID / FLUX CORED
STAINLESS SOLID / FLUX CORED
Wire Diameter
1.2
0.8/1.0/1.2
1.0/1.2/1.6
Initial Current
OFF
ON / OFF
Welding Voltage Adjustment
INDIVIDUAL
SYNERGIC / INDIVIDUAL
●
Internal Function refer to section “10.2.1 Setting of Internal Function” for more details-
F
Function
Initial value
Setting range
F1
Fine adjustment of anti-stick(burn-back) time
0
-50 (0.50
sec. decrement) –50 (0.50
sec.
incremental)
F2
Fine adjustment of anti-stick(burn-back) voltage
0.0
-9.9–9.9 V
F3
Fine adjustment of slow wire feed
0.0
−1.0–1.0 m/min.
F4
Switch of Auto/Semi-automatic mode
0
0 (semi-auto mode)/ 1(auto1)/ 2(auto2)
F5
External command 10
V MAX
OFF
ON(valid) / OFF(invalid)
F6
Setting of up-slope time
0.0
0–10.0
sec.
F7
Setting of down-slope time
0.0
0–10.0
sec.
F8
Setting of Result display holding time
20
0–60
sec.
F9
-
-
-
F10
Disabling Power saving function
OFF
ON (valid) / OFF (invalid)
F11
Setting of fine adjustment for welding condition
memory
OFF
ON (valid) / OFF (invalid)
F12
Setting of soft arc mode
OFF
ON (valid) / OFF (invalid)
F13
Setting of CONSTANT PENETRATION
OFF
ON (valid) / OFF (invalid)
F14
Selection of wire feeder
0
0
:
WF 04(22m/min)
F15
INITIAL CONDITION setting
OFF
ON (valid) / OFF (invalid)
F16
Gas pre-flow time
0.1
0 – 10
sec
F17
Gas post-flow time
0.4
0 – 10
sec