30
-
10. OPERATION
(Continued)
CAUTION
⚫
This welding machine should be operated by persons only after reading and
understanding contents of this owner’s manual and having knowledge and skills for
handling the welding machine safely.
⚫
Use this welding power source at or under the rated duty cycle. Exceeding the rated duty
cycle limitation may result in damage to the welding machine
.
When reading the operating instructions described below, unfold Section 14.3 “Initial value and
Setting Range” so that you can read them confirming the location of the key on the digital panel.
10.1 Basic setting
10.1.1 Setting of Welding Condition
Set a welding mode by using GAS select key[1], WIRE TYPE select key[2] and WIRE DIA. select
key[3] in accord with customer needs. The optional modes are shown in the table below.
○
: Supported -: Not supported
Welding Method
Wire Diameter
(mm)
CPTX-I 400 2W
CPTX-I 500 2W
Type of Welding Wire
Gas
STEEL SOLID
CO
2
○
-
Ø 1.0
○
○
Ø 1.2
○
○
Ø 1.6
-
○
STEEL SOLID
MAG
Ø 0.8
○
-
Ø 1.0
○
○
Ø 1.2
○
○
Ø 1.6
-
○
STEEL FLUX-CORED
CO
2
Ø 1.2
○
○
Ø 1.6
-
○
STEEL FLUX-CORED
MAG
Ø 1.2
○
○
STAINLESS SOLID
MIG
Ø 0.8
○
-
Ø 1.0
○
○
Ø 1.2
○
○
Ø 1.6
-
○
STAINLESS
FLUX-CORED
CO
2
Ø 1.2
○
○
Ø 1.6
-
○
DC STICK
-
-
○
○
NOTE 1: MAG gas refers to a mixed gas of 80% argon(Ar) and 20% carbon
dioxide(CO
2
)gas.
NOTE 2: MIG gas refers to a mixed gas of 97,5% argon(Ar) and 2,5% carbon
dioxide(CO
2
)gas.