50
-
10. OPERATION
(Continued)
[2] Method for Releasing a Password Lock
(1)
When in the password lock state, after long pressing the ENTER key[14] to release the lock,
the digital meters will display “PAS PAS” for 2
seconds before switching to the password
input mode.
(2)
After switching to the password input mode, the left display meter will blink “Loc”, the right
digital meter will display
“
000” with the hundreds digit blinking. Press DISPLAY CHANGE
key[7] to switch to a blinking digit (hundred’s place, ten’s place, unit’s place), and then use
the parameter adjusting knobs([4],[5]) to enter the password number corresponding to the
blinking digit.
Note: To change the password, you need to input the current password correctly
before setting new password.
(3)
After completion of password input, press ENTER key[14]. If the password input is correct,
“good” will be displayed and the password lock state will be released.
In addition, when in a password setting mode, now you can go to the step (2) in section [1]
above to set a new password.
If the password input is wrong, “bAd” will be displayed with the lock not released, and you
need to input the correct password again or exit the password input mode.
[3]
Method for Canceling Password Input
To cancel the password setting or input mode, turn off the power source. In such case, the
password can not be set.
If the power source is in the input password mode to un-lock, press ARC CONTROL key[8] to
cancel password input. In such case, the lock state can not be released.
Blinking
Blinking
Blinking
Blinking