10. OPERATION
(Continued)
3) Display of Welding Results After Completion of Welding
After completion of welding, the average output current and voltage of the last one second
blink for about 20 seconds (however, the output condition of crater filler are ignored). The
welding operator can verify the welding conditions according to such display after completion
of welding, and such results can also be used as approximate values for condition adjustment.
Such display can be canceled after completion of welding by starting another welding or by
pressing any key on the control panel without the 20 seconds delay.
The result display time can be set by internal function “F8”, wherein the left digital meter
displays setting value and the “sec” LED lights up. The setting range for the result display
time is 0–60 seconds.
NOTE: In the case where the less than one-second welding such as tack welding, etc.
is performed, the correct results of the welding are not displayed.
4) Display of an Abnormality When It Occurs
If an error is detected in the power source, an error number indicating error message blinks.
See Section“12.4 How to Solve an Error ”for details.
NOTE: The average output current and voltage displayed by the digital meters are for
reference only, and it is not guaranteed that they can be used as metering
management data.
10.1.12 Using the Analog Remote Control
When the switch on the analog remote control box is set to “ON”, the adjusting knobs of
current and voltage of analog remote control box begin to work, and the setting of the remote
control box will display on the digital meter, meanwhile the adjust knob for adjusting current
and voltage on the control panel can not be operated.
When the switch on the analog remote control box is set to “OFF”, the adjusting knobs of
current and voltage of control panel begin to work, and the setting of the control panel will
display on the digital meter, meanwhile the adjust knob for current and voltage on the analog
remote control box can not be operated.
Setting switch for remote
control box / panel
WELDING VOLTAGE adjusting
knob:
When [9] key of front panel is
set “SYNERG”, “0%” position
of this knob means standard
voltage setting. If voltage is
unmatched, please turn the
knob to right (+) – voltage
increase, to lest (-) –voltage
decrease
Panel of Analog Remote Control for CPTX-I 400/500 2W
Setting switch for JOB memory function:
Set “JOB”, welding parameter data from
NO.1 to NO.10 can be read from current
knob.
WELDING CURRENT
adjusting knob:
Use this knob to set a
welding current or
select JOB MEMORY
number.
INCHING SWITCH:
press this switch to feed wire.
Rotate the current setting knob