1.4 Welding mode lists
Welding mode
Welding
process
Gas
Wire
material
Wire
diameter
Travel
speed
Notes
Number of welding
Welding mode description
characteristic data
in AX21/FD11
Extended
cable
500A Mig_2 DC
φ
1.2 Ferrite (Low*)
$WTBD4290
DC MIG
※
2 Ferrite
1.2
〃
MIG
※
3 Cu-Si
0.8
〃
500A Mig_3 DC
φ
0.8 Cu-Si (Low*)
$WTBD4291
〃
〃
〃
1.0
〃
500A Mig_3 DC
φ
1.0 Cu-Si (Low*)
$WTBD4293
〃
〃
〃
1.2
〃
500A Mig_3 DC
φ
1.2 Cu-Si (Low*)
$WTBD4294
〃
〃
Cu-Al 0.8
〃
500A Mig_3 DC
φ
0.8 Cu-Al (Low*)
$WTBD4295
〃
〃
〃
1.0
〃
500A Mig_3 DC
φ
1.0 Cu-Al (Low*)
$WTBD4297
〃
〃
〃
1.2
〃
500A Mig_3 DC
φ
1.2 Cu-Al (Low*)
$WTBD4298
※
1 90%Ar, 10%CO
2
※
2 97.5%Ar, 2.5%CO
2
※
3 100%Ar
※
4 98%Ar, 2%O
2
POINT
Normally, use the welding characteristic data given in
Table 1.4.20 dedicated to
“High” application. The ones for “Standard” application must be used only when the
welding speed is low (50cm/min or lower in general), which causes unstable welding
performance.
Also, welding performance may become unstable when using the extended power cable
depending on the layout condition of cables (when the total length exceeds 30m or the
cable is coiled). In that case, voltage adjustment will normally bring about stable
condition. However, use the welding characteristic data dedicated to “Standard:
extension” application if the welding performance is not yet stable. In order to register
“Standard: extension” application, change the operator qualification to “
SPECIALIST
”.)
1-77
Summary of Contents for OTC Almega AX Series
Page 10: ......