2.1 Connect Welding Interface (Digital)
2-5
2.1.4 Connection of Control cable 4
Connect each connector of the control cable 4 to the socket ICN4 for wire feeder on the welding
power source and to the connector CN4 on the rear panel of the manipulator, respectively.
2.1.5 Connection of Workpiece side welding cable / Torch side welding cable
Connect the cable respectively referring to “CONNECTION PROCEDURE AND GROUND FOR
SAFETY USE” in the instruction manual of each welding power source.
CAUTION
Installation of the welding power source and welding cables
Fix the welding power source on a firm and level surface, such as a concrete floor,
rendering it immovable.
Wire the welding cable with some margin, so that no unreasonable force is applied to
the connector of the welding cable.
If you bend the connector section forcedly for wiring, it may cause damage of the
connector.
(Good example)
(Wrong example)
In case of installation on the floor:
Provide some margin in wiring so as to
avoid any force applied to the connector.
In case of forced wiring of the welding
cable:
If you bend the connector section
forcedly for wiring, force is applied to the
connector.
Welding cable
Welding
power
source
Welding cable
Welding
power source
Floor surface
Floor surface
In case of installation on a mount, etc:
Place it sufficiently away from the mount
edge or take other measures, so that no
force is applied to the connector.
In case of installation near the mount
edge:
The connector may be pulled under the
weight of the welding cable and
subjected to force.
Welding cable
Welding
power source
Floor surface
Mount
Wide margin
Welding cable
Welding
power
source
Floor surface
Mount
Mount
edge
2.1.6 Connection of Gas hose
Connect the gas hose to the connector GAS on the rear side of the manipulator and to the gas
regulator, respectively.
Summary of Contents for OTC Almega AX Series
Page 10: ......