3.6 Check the configuration
3-20
3.6 Check the configuration
Use the following procedure to check that the configuration up to section 3.5 was performed correctly.
Writing the setup data onto the robot controller
1
Turn OFF the power of the robot controller and welding power source.
2
Turn ON the power of the welding power source.
>> Check that "000 000" blinks on the front panel of the welding power source.
If different from above, refer to "Chapter 2 Connections", and check that control
cable 5 is connected, and that the STOP (+) / STOP (-) jumper wire of terminal block
TM3 on the PCB10 printed circuit board of the Welbee Inverter series welding power
source is removed.
3
Turn ON the power of the robot controller.
>> On the teach pendant (TP) of the robot controller, check that the starting process
has completed and that the robot controller is ready for operation.
>> Next, check on the TP that no errors related to the welding power source have
occurred, such as "A5013 Power of arc welding power source not ON."
If different from above, refer to "Chapter 2 Connections" and "Chapter 4
Maintenance", and check that the interface and the robot controller, and the interface
and the welding power source are connected correctly. Also, perform "3.5 Writing the
setup data" again.
4
Check that the emergency stop is not being input to the robot controller, and
check whether errors other than those described above have occurred.
If the emergency stop is being input, cancel it.
If an error has occurred, troubleshoot by referring to the instruction manual of the
robot controller.
5
Check that the front panel display of the welding power source is as follows.
(1) The "000 000" blinking has gone off.
(2) The dots to the bottom right of the left and right digital meters are
blinking.
(3) The display indicating the welding mode (wire diameter, material and gas)
is the last welding mode (mode with the highest registration number) that
was registered in "3.4.2 Configuring the welding mode for the Welbee
Inverter series welding power source".
If different from (1) above, refer to "Chapter 2 Connections" and check that the
interface is connected correctly.
If different from (2) or (3) above, refer to "Chapter 4 Maintenance" and check that no
errors have occurred for the interface. Also, perform "3.3 Configuring the robot
controller" to "3.5 Writing the setup data" again.
6
Operate the TP of the robot controller to check that the gas check and the
inching/retracting of the welding wire was executed correctly.
If different from above, check that "3.3 Configuring the robot controller" was
performed correctly.
>> The setup operations were completed correctly.