![Daihen OTC Almega AX Series Instruction Manual Download Page 166](http://html1.mh-extra.com/html/daihen/otc-almega-ax-series/otc-almega-ax-series_instruction-manual_3204476166.webp)
3.12 Welding conditions of WB-W350/W400
3-55
Table 3.12.4 Setting manner for each function
Function name
Function
type
Function
number
Function
Initial
value
WIF-Digital function
ON/OFF
A
1
It switches ON/OFF for the
function in this table.
ON
:
Available
OFF
:
Not available
OFF
Penetration
adjustment function
A
2
It switches ON/OFF for the
penetration adjustment function
of the welding power source.
ON
:
Available
OFF
:
Not available
OFF
Process in the fan
failure / Process in
the shortage of input
voltage
F
19
It designates the process on the
robot side when the welding
power source detects the fan
alarm or the shortage alarm of
input voltage.
ON
:
Indicates the error by
“Alarm”.
OFF
:
Not detecting the error.
OFF
Arc voltage direct
detection
F
38
Set this function ON when
connecting the voltage detection
cable for directly detecting the
arc voltage (
-
) to the welding
power source.
1
:
Available
0
:
Not available
0
Summary of Contents for OTC Almega AX Series