User's Manual
237
Parameter
Description
Encryption Type
Select the encryption type from NONE, SSL, or TLS.
For SMTP server, the default encryption type is TLS.
Interval (Sec.)
Set the interval at which the system sends an email for the same
type of alarm event to avoid excessive pileup of emails caused by
frequent alarm events.
The value ranges from 0 to 3600. 0 means that there is no interval.
Health Mail
Enable the health test function. The system can send a test email
to check the connection.
Sending Interval
Set the interval at which the system sends a health test email.
The value ranges from 30 to 1440. 0 means that there is no
interval.
Test
Click Test to test the email sending function. If the configuration is
correct, the receiver’s email account will receive the email.
Before testing, click Apply to save the settings.
Step 4 Click Apply.
5.11.13 SNMP
You can connect the Device with some software such as MIB Builder and MG-SOFT MIB
Browser to manage and control the Device from the software.
Prerequisites
●
Install the software that can manage and control the SNMP, such as MIB Builder and
MG-SOFT MIB Browser
●
Obtain the MIB files that correspond to the current version from the technical support.
This function is available on select models.
Procedure
Step 1 Select Main Menu > NETWORK > SNMP.
Summary of Contents for N41C1P
Page 1: ...Network Video Recorder User s Manual Dahua North America V2 3 1...
Page 235: ...User s Manual 219 Figure 5 179 TCP IP Step 2 Click to configure the NIC card and then click OK...
Page 286: ...User s Manual 270 Figure 5 229 Pattern login...
Page 346: ...User s Manual 330 Figure 5 290 Shutdown 2...
Page 377: ...User s Manual Dahua Technology USA 15245 Alton Parkway Irvine CA 92618 949 679 7777...