User's Manual
223
Procedure
Step 1 Select Main Menu > NETWORK > Port.
Figure 5-182 Port
Step 2 Configure the parameters.
The parameters except Max Connection take effect after the Device restarts.
Table 5-51 Port parameters
Parameter
Description
Max Connection
The allowable maximum clients accessing the Device at the same
time, such as web client, platform, and mobile client.
TCP Port
Transmission control protocol port. Enter the value according to
your actual situation.
UDP Port
User datagram protocol port. Enter the value according to your
actual situation.
HTTP Port
The default value setting is 80. You can enter the value according to
your actual situation.
If you change the HTTP port number to, for example, 70, then you
need to enter 70 after the IP address when logging in to the Device
through the browser.
HTTPS Port
HTTPS communication port. The default value is 443. You can enter
the value according to your actual situation.
RTSP Port
The default value is 554. You can enter the value according to your
actual situation.
POS Port
POS data transmission port. The value range from 1 through 65535.
The default value is 38800.
Step 3 Click Apply.