Figure 6-72 Relay Activation
Step 2.
Select Enable.
Step 3.
Set alarm parameters.
Please refer to the following sheet for log parameter information.
Parameter
Function
Relay-in
Support 2 channels of alarm input.
Period
Set alarm arm and disarm period. Click on setup button to open period menu.
Anti-dither
During anti-dither period, only one alarm will be recorded. Unit is second with range
0s
~
100 s.
Sensor type
May set NO or NC.
Chart 6-28
Step 4.
Select Relay-out accordingly, and set port no. and alarm delay time.
Step 5.
Click OK.
6.5.4.1.2 Relay-out
Summary of Contents for ITC231-RF1A-IR
Page 13: ...Chart 2 1 2 2 Side Panel Figure 2 2 2 3 Front Panel Figure 2 3 ...
Page 18: ...4 System Network Please refer to Figure 4 1 Figure 4 1 Figure 4 2 ...
Page 19: ......
Page 81: ...Figure 6 64 Step 3 Click Next see Figure 6 65 Figure 6 65 ...
Page 84: ...Figure 6 68 2 Click Install Certificate See Figure 6 69 ...
Page 85: ...Figure 6 69 3 Click Next see Figure 6 70 Figure 6 70 ...